3
.
A
d
j
ust
t
h
e
T
R
IGG
ERLEVEL
control
to
ob
tain
α
sta
b
le
dis
p
lay
.
4
.
Set
t
he
S
E
C/DI
V
switc
h
to
dis
p
lay
one
complete p
e-
r
iod
of
t
he
waveform
.
E
nsure
t
h
at
t
h
eSE
C/DI
V Va
r
iable
control
is
in
t
he
CA
L
d
etent
.
5
.
P
osition
t
he
display
to
p
lace
t
he
time-measurement
p
oi
n
ts
on
t
he
center
ho
r
izo
n
tal
graticule
line
(see
F
igure
4-5)
.
6
.
M
easure
t
h
e
H
o
r
izo
n
tal
dista
nce
between
t
he
time-
meas
u
reme
n
t
p
oi
n
ts
.
7
.
Calculate
time
d
u
ratio
n u
sing
t
h
e
followi
ng
fo
r
mula
:
h
orizo
n
tal
S
E
C/DI
V
d
ista
nce χ
switc
h
Time
(divisio
n
)
setting
Duration
mag
n
ification
factor
E
XA
MPLE
:
T
he
d
ista
nce b
etwee
n
t
h
e
time
meas
urement
points
is
8
.3
divisions
(see
F
igure
4-5),
and
t
he
SE
C/DI
V
switc
h
is
set
to
2
ms
p
er
d
ivision
.
T
he
Χ
10
M
agn
ifier
is
off
(
knob
in)
.
Substit
u
ting
t
h
e
given
val
ues
:
Time
Duration
=
8
.3
d
iv
χ 2
ms/div
=
16
.6
ms
Fr
eque
n
cy
T
h
e
fre
quency
of
α
recu
r
rent
signal
ca
n
b
e
determined
f r
om
its
time-
d
uration
meas
u
reme
n t
as
follows
:
1
.
M
easure
t h
e
time
duration
of
one
waveform
cycle
us-
ing
t
h
e
preceding
"Time
Duration"
measurement
procedure
.
2
.
Calculate
t
h
e
reci
p
rocal
of
t
he
time-du
r
atio
n
value
to
determine
t
he
fre
que
n
cy
of
t
he
waveform
.
E
XAMPLE
:
T
he
signal
in
F
igure
4-5
h
as α
time
du
ratio
n
of
16
.6
ms
.
Calculating
t
h
e
reci
p
rocal
of
time
du
r
ation
:
F
re
q
uency
=
1
=
1
=
60 Hz
time
d
uration
16
.6
ms
Rise
Time
Rise-time
measureme
n
ts
use
t
h
e
same
met
h
ods
as
time
duration,
exce
p
t
t
h
at
t h
e
measureme
n
ts
a
r
e
ma
de
between
t
h
e
10%
and
90%
p
oi
n
ts of
t
he low
to
h
ig
h
tra
n
sition
of
t
h
e
selected
waveform
(see
F
igu
r
e
4-6)
F
all
time
is
measured
between
t
h
e
90%
a
nd
10%
p
oints
of
t
h
e
h
ig
h
to
low
tra
n
si-
tion
of
t
he
waveform
.
1
.
P
reset
instrument
controls
and
ob
tain
α
b
aseline
trace
.
2
.
Apply
an
exact
5-division
sig
n
al
to
eit
h
er vertical-
ch
annel
i
np
ut
conn
ecto
r
and
set
t
h
e
VER
TICA
L
M
OD
E
switc
h
to
d
is
p
lay
t
h
e
c
h
annel
u
sed
.

Other manuals for Tektronix 2213A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 2213A and is the answer not in the manual?

Tektronix 2213A Specifications

General IconGeneral
BrandTektronix
Model2213A
CategoryTest Equipment
LanguageEnglish

Related product manuals