EasyManuals Logo
Home>Tektronix>Test Equipment>2213A

Tektronix 2213A Operator's Manual

Tektronix 2213A
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
6
.
Select
ADDVER
TICA
L
M
OD
E and press
i
n
t
h
e
I
NVER
T
button,
and
slig
h
tly
read
ju
st
t
he
CH
2
V
O
L
TS/DI
V
V
a
r
iable
control
for
maxim
u
m
cancellation
of
t
he un
d
esire
d
signal
com
p
onent
(see
Figure
4-3
Β
)
.
Am
p
lit
u
de
Compariso
n
(
R
atio)
In
some
a
pp
lications
it
may
be necessary
to
esta
b
lis
h
α
set
of
d
eflection
factors
ot
h
er
t
han
t
h
ose
indicated
by
t
h
e
V
O
LTS/DI
V
switc
h
settings
.
T
h
is is
u
seful
for
com
p
aring
un
k
nown
signals
to
α
reference
signal
of
k
now
n
am
p
lit
ude
.
To
accom
p
lis
h
t
h
is,
α
refere
nce
signal
of
kn
own
amplitude
is
first
set
to
an
exact
num
b
er
of
vertical
divisions
b
y a
dj
usti
ng
t
h
eV
O
LTS/DI
V
switc
h
and
V
aria
b
le
con
trol
.
Un
k
nown
sig-
n
als
can
t h
en be
q
uic
k
ly
and
accurately
com
p
are
d
wit
h
t
h
e
reference
signal
wit
h
out
distur
b
ing
t
h
e
setting
of
t
h
e
V
O
LTS/DI
V
V
ariable
control
.
T
h
is
procedure
is
as
follows
:
1
.
Pr
eset instrume
n
t
controls
and
obtai
n
α
baseline
trace
.
2
.
Apply
t
he
r
efe
r
ence
signal
to
eit
h
er
vertical
c
h
annel
in
p
ut
and
set
t
he
VER
TICA
L
M
OD
E
switc
h
to
display
t
he
ch
annel
used
.
3
.
Set
t
h
e
am
p
litude
of
t
h
e
refe
r
ence
signal
to
five
verti-
cal
divisions
b
y
ad
j
usti
ng
t
he
V
O
L
TS/DI
V
switc
h a
n
d
V
O
L
TS/DI
VV
ariable
control
.
4
.
Disconnect
t
h
e
reference
signal
and
apply
t
h
e
un-
known
signal
to
b
e
measure
d
to
t
he
same
chann
el
i
npu
t
.
Ad
j
ust
t
he
ve
r
tical
p
osition
of
t
he
waveform
so
t
h
at
its
b
ot-
tom
edge
just
touc
h
es
t
he
0°/
ο
line
on
t
he
crt
.
5
.
Horizontally
position
t
he
waveform
so
t
h
at
its
top
most
features
cross
t
he
center
vertical
graticule
li
n
e
(see
Figu
r
e
4-4)
.
6
.
R
ead
t
he percen
t
ratio
directly
from
t
he
gra
du
ations
of
t
he
center
li
n
e,
referring
to
t
he
0%
an
d
100%
percentage
mar
ks on
t
h
e
left
edge
of
t
he
graticule
(1
minor
division
eq
uals
4%
for
α
5-
d
ivision
dis
p
lay)
.
TIME
ME
AS
UREMEN
TS
Time
Du
r
ation
To
measure
time
b
etween
two
points
on
α
waveform,
use
t
h
e
following
procedure
.
/
1
.
Preset
i
n
strument
controls
and o
b
tai
n
α
b
aseline
t
r
ace
.
2
.
Apply
t
he
signal
to
eit
h
er
ve
r
tical-c
han
nel
input
con-
n
ector
and
set
t
he
VER
TICA
L
M
OD
E
switc
h
to
dis
p
lay
t
he
ch
annel
used
.

Other manuals for Tektronix 2213A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 2213A and is the answer not in the manual?

Tektronix 2213A Specifications

General IconGeneral
BrandTektronix
Model2213A
CategoryTest Equipment
LanguageEnglish

Related product manuals