General
Information
-
2221
Operators
Table
1-2
(
cont
)
Characteristics
Performance
Requirements
Aberrations
(
NON
-
STORE
and
STORE
in
SAMPLE
Mode
)
2
mV
per
division
to
50
mV
per
division
+
4
%
,
-4
%
,
4
%
p
-
p
.
3
%
or
less
at
25
°
C
with
cabinet
installed
.
0.1
V
per
division
to
0.5
V
per
division
+
6
%
,
-6
%
,
6
%
p
-
p
.
5
%
or
less
at
25
°
C
with
cabinet
installed
.
1
V
per
division
to
5
V
per
division
+
12
%
,
-12
%
,
12
%
p
-
p.a
10
%
or
less
at
25
°
C
with
cabinet
installed
.
Measured
with
a
five
-
division
reference
signal
,
with
the
top
of
the
square
wave
centered
vertically
,
from
a
50
-
ohm
source
driving
a
50
-
ohm
coaxial
cable
terminated
in
50
ohms
at
the
input
connec
tor
,
and
VOLTS
/
DIV
Variable
control
in
the
CAL
detent
.
NON
-
STORE
Bandwidth
(
-3
dB
)
°
C
to
+
35
°
C
5
mV
per
division
to
5
V
per
division
Dc
to
at
least
60
MHz
.
2
mV
per
division
Dc
to
at
least
50
MHZ
.
+
35
°
C
to
+
50
°
C
5
mV
per
division
to
5
V
per
division
Dc
to
at
least
50
MHz
.
a
2
mV
per
division
UU
Dc
to
at
least
50
MHz.a
Measured
with
a
six
-
division
reference
signal
,
centered
vertically
,
from
50
-
ohm
source
driving
a
50
-
ohm
coaxial
cable
terminated
in
50
ohms
at
the
input
connector
and
the
probe
input
,
and
VOLTS
/
DIV
Variable
control
in
the
CAL
detent
.
NON
-
STORE
BW
LIMIT
(
-3
dB
)
10
MHz
+
15
%
.
AC
Coupled
Lower
Cutoff
Frequency
10
Hz
or
less
at
-3
dB.a
Useful
Storage
Performance
RECORD
,
SCAN
,
and
ROLL
Store
Modes
SAMPLE
Acquisition
,
no
AVERAGE
Single
Trace
CHOP
/
ALT
5
us
/
div
to
5
s
/
div
10
Hza
SEC
/
DIV
5
Hza
SEC
/
DIV
EXT
CLOCK
(
up
to
1
kHz
)
EXT
Hza
10
EXT
Hza
20
Useful
storage
performance
is
limited
to
the
frequency
where
there
are
ten
samples
per
sine
-
wave
signal
period
at
the
max
imum
sampling
rate
.
This
yields
a
maximum
amplitude
uncer
tainty
of
5
%
.
Max
sampling
rate
is
20
MHz
in
Single
trace
and
10
MHz
in
CHOP
or
ALT
at
a
SEC
/
DIV
setting
of
5
us
per
division
.
Accuracy
at
useful
storage
performance
limit
is
measured
with
respect
to
a
six
-
division
50
kHz
reference
sine
wave
.
u
*
pertormance
Requirement
not
checked
in
manual
.
1-4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 2221 and is the answer not in the manual?

Tektronix 2221 Specifications

General IconGeneral
BrandTektronix
Model2221
CategoryTest Equipment
LanguageEnglish

Related product manuals