EasyManuals Logo
Home>Tektronix>Test Equipment>454A

Tektronix 454A User Manual

Tektronix 454A
365 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
Temper at ur e
O
p
er at i ng
E
l ect r omag
n
et i c
I
n
t er f er e
n
ce
(
M
OD163D
Onl y) As
Test ed
I n
MI L- 1- 6181D
Tr ans
p
or t at i on
Al t i t u
d
e
O
p
er at i ng
H
umi
d
i t y
V
i
b
r at i on
S
h
oc
k
Non- Oper at i ng
R
a
d
i at ed
I nt er f er ence
Con
d
uct e d I nt er f er ence
Non- Oper at i ng
O
p
er at i
ng
and
St or age
O
p
er at i ng
O
p
er at i ng
and
Non- Oper at i ng
C
h
ar act er i st i c
- 15
0
C
t o
+55
0
C
- 55
0
C
t o
+75
0
C
TA
BLE
1- 2
ENV
I
R
O
NMEN
TA
L
P
er f or mance
R
a
d
i at e
d
I nt er f er ence
f r om
t
h
e
i nst r u-
ment
un
d
er t est
wi t h
i
n
t
he
gi ve
n
l i mi t s
f r om
150
kH
z
t o
1000
MH
z
.
Co
nd uct e d
i
n
t er f er e
nce
t
h
r oug
h
t
h
e
p
ower
cor d wi t h
i n
t
he gi ven
l i mi t s
f r om
150
kH
z
t o
25
MH
z
.
Qual i f i e
d
un
d
er
N
at i onal
Saf e Tr ansi t
Commi t t ee
t est
pr oce d ur e
1zyxwvutsrqponmlkjihgfedcbaZYXWVUTSRQPONMLKJIHGFEDCBA
wi t h ±
30- i nc h d
r o
p
.
To
15, 000
f eet
.
M
axi mum
al l owabl e
am
b
i ent
t em
p
er at ur e
d ecr eased
by
1 °
C/ 1000
f eet
f r om
5, 000
f eet
t o
15, 000
f eet
.
To
50, 000
f eet
.
5 cycl es
( 120
h
our s)
t o
95%
¿
r el at i ve
h
umi di t y
r ef er enced
t o
MI L- E- 16400
F
.
F
i f t een
mi nut es
al ong
eac
h
of
t
he
t
h
r ee
ma
j
or
axes
at
±
t ot al
d
i s
p
l ace-
ment
of 0 . 025
i nc
h pea k t o p
ea
k
( 4
g' s
at
55
H
z)
wi t h
f r equency
var i ed
f r om
10 t o
55
H
z i n
one
mi nut e swee
p
s
.
H
ol
d
f or
3
mi nut es
at
55
H
z
.
Al l
ma
j
or
r esonances
must
b e
above
55
H
z
.
30
g' s,
1/ 2
si ne,
11
ms d
ur at i on,
2
s
h
oc
k
s
p
er
axi s
eac h
di r ect i on
f or
±
t ot al
of
12
s
h
oc
k
s
.
S
p
eci f i cat i on- 454
/
R
454A
Su
pp
l ement al
F
an
at
r ear
ci r cul at es
ai r
t
h
r oug
h
out
i nst r
u
ment
.
Aut omat i c
r eset t i
ng
t
h
er -
mal cut out
p
r ot ect s
i nst r ument
f r om
over
h
eat i ng
.
F
or
i nst r ument s
eq
ui
pped
wi t h r un-
ni ng
t i me
met er s, d
er at e
non- oper at i ng
l ow
t emper at
u
r e
t o
- 30
0
C
.

Table of Contents

Other manuals for Tektronix 454A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 454A and is the answer not in the manual?

Tektronix 454A Specifications

General IconGeneral
BrandTektronix
Model454A
CategoryTest Equipment
LanguageEnglish

Related product manuals