These specifications apply to all AFG3000C and AFG3000 Series Arbitrary
Function Generators, unless otherwise stated. All specifications are guaranteed
unless label
ed “typical”. Typical specifications are provided for your convenience
but are not guaranteed.
Specificati
ons that are check marked with the
symbol are checked directly (or
indirectly) in the Performance Verification section.
All specifi
cations apply to the arbitrary function generator unless noted otherwise.
These specifications are valid under the following conditions:
The instr
ument must have been calibrated/adjusted at an ambient temperature
between +20 °C and +30 °C.
The inst
rument must be operating at an ambient temperature between 0 °C
and +50 °C.
The ins
trument must have had a warm-up period of at least 20 minutes.
The instrument must be in an environment with temperature, altitude, and
humid
ity within the operating limits described in these specifications.
Electrical specications
Tabl
e 2: Operating mode
Characteristic Description
Run
mode
Continuous, Modulation, Sweep, and Burst
Bur
st count
1 to 1,000,000 cycles or innite
In
ternal trigger rate
1.
000 μs to 500.0 s
AFG3000C and AFG3000 Series Specifications and Performance Verification 5

Table of Contents

Other manuals for Tektronix AFG3102

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix AFG3102 and is the answer not in the manual?

Tektronix AFG3102 Specifications

General IconGeneral
BrandTektronix
ModelAFG3102
CategoryPortable Generator
LanguageEnglish

Related product manuals