Page #29 background image
Service Administrative Support
4691
INSTALLATION
AND
SPIRAL
HOSE
DISPOSITION
(CONT.)
Attach
air
line here
Ink
Jet
Head
Assembly
w2
Issue
13-19
4691
LOW
INK
LEVEL
DETECTION
ADJUSTMENT
Ref:
070-4498-00,
4691
Service
Manual
The
4691
low
ink
level detection ad-
justment
on
page
5-16
of the service
manual
is incorrect
as
far
as
the
voltage levels are concerned.
The
ink
that
is
now
used
with the
4691
requires
that
different
detection levels
be
used
for
each
color of ink.
The
voltages are
changed
as
follows:
1.
Magenta,
VRl
is
adjusted
so
that
the voltage
on
RlO
is
.8Vdc.
2.
Cyan,
VR2
is
adjusted
so
that
the
voltage
on
R16
is
.3Vdc.
3. Black,
VR3
is
adjusted
so
that
the
voltage
on
R22
is
.6Vdc.
October,
1883
laaue 31
4.
Yellow,
VR4
is
adjusted
so
that
the
voltage
on
R28
is
.4Vdc.
All
4691
1
s
that
are shipped
from
the
factory
have
been
adjusted to the
correct voltage levels.
A correction to the service
manual
is
being
made.
w2
Issue
13-18
-26-
)