Get Acquainted with the Instrument
Front-Panel Connectors
1. Logic Probe Connector (on
MSO4000 models only)
2. Channel 1, 2,(3, 4 ). Channel inputs with
TekVPI Versatile Probe Interface.
3. Aux In. Trigger level range is adjustable
from +8 V to –8 V. The maximum input
voltage is 400V peak, 25 0V RMS. Input
resistance is 1 M ± 1% in parallel with
13 pF ±2 pF.
4. PROBE COMP. Square wave signal
source to compensate probes. Output
voltage: 0 2.5V, amplitude ± 1% behind
1k ±2%. Frequency: 1 kHz.
5. Ground.
6. Application Module Slots.