It is possible to connect the wood-burning stove to chimneys that are also
used for other purposes. However, the concrete conditions must be assessed
by the fitter and/or chimney sweep.
If the stove is to be mounted with back exit the following is done:
The round, welded or screwed cover plate at the back of the stove is removed.
Then the cut-out piece on the base-plate is removed (the thin division plate).
Be careful not to drop the piece between the back plate and the stove! This is
best done with a screwdriver / chisel or pliers.
Finally the screwed smoke cover is removed and then the exhaust branch can
be mounted.
Remember to fix the smoke cover at the top of the stove before use.
Demands for the floor:
The foundation must be able to bear the stove and possibly the chimney’s
weight.
Regulations:
When your new stove has been mounted the installation has to be reported to
the local Hetas installer / Building control. The Hetas installer / Building control
must inspect the installation and clean the chimney in the future.
2. LIGHTING INSTRUCTION
The first time:
The first time the stove is lit is must be done gently as all the materials need
to get use to the heat. The Senotherm varnish that the stove is painted with
will harden the first couple of times the stove is heated, and it may cause
some odour nuisances. So make sure that you have proper ventilation. Do not
touch the painted surface, when the stove is hot. The painting has to harden
up first.
Use of the stove:
Below is the procedure used for testing/approval of the stove. It is this
procedure that will lead to the best combustion for the given chimney.
Firewood amount and damper setting can be adjusted to the individual need
for heating and the draught in the concrete chimney.
On your new TT10 / TT10S the work with controlling the air input has been
simplified so there is only one knob/damper (below the door).
Between the left position and the middle position you have the normal area
where you control the air input. No air input = left position and maximum
air input = middle position.