SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
CAUTION: THIS PRODUCT IS INTENDED FOR
GENERAL VENTILATING USE ONLY. DO NOT
USE TO EXHAUST HAZARDOUS OR
EXPLOSIVE MATERIALS OR VAPORS.
A. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
B. Before installing, servicing or cleaning the unit, dis-
connect power cord.
C Installation work and electrical wiring must be done
by qualified person(s) in accordance with all appli-
cable codes & standards, including fire-rated con-
struction.
D. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
UNIVERSAL COOK’N’VENT
®
INSTALLATION INSTRUCTIONS
MODELS: CVS30R • CVS36R • CVS45R
Rating: 120 Volt, 60 Hz.,10.2 Amps.
For Integral Blower Installations:
• Requires Integral Blower: Model # VTN600CVR
• Requires Discharge Duct Size 3
-1
/4" x 10"
• Requires Power Supply • 120 Volt • 15-20 Amps., 3 prong receptacle • 60 Hz., AC.
• See Steps 3 and 5 for electrical receptacle and duct outlet location
For Remote Blower Installations:
• Requires Remote Blower: Model # VTR1000Q or VTR600R
• Requires Duct Transition: Model # CVD310 (for 3
-1
/4" x 10" duct) or CVD314 (for
3
-1
/4" x 14" duct)
• Requires 4 wires and 1 ground wire connecting blower and vent
• Requires Power Supply • 120 Volt • 15-20 Amps., 3 prong receptacle • 60 Hz., AC.
• Requires 10" round ducting to connect to VTR1000Q Remote Blower or 8" round
for VTR600R
• See Steps 3 and 5 for electrical receptacle and duct outlet location
INSTALLATION MUST COMPLY WITH ALL APPLICABLE CODES.
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
IMPORTANT: Save these instructions for the local electrical inspector's use.
INSTALLER: Please leave these Installation Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
SAFETY WARNING: Disconnect power by removing plug from receptacle before installing or
servicing this unit.
burning equipment to prevent backdrafting. Follow
the heating equipment manufacturers guideline and
safety standards such as those published by the Na-
tional Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local
code authorities.
E. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
F. Caution — To reduce risk of fire and to properly
exhaust air, be sure to duct air outside. Do not vent
exhaust air into spaces within walls, ceilings, attics,
crawl spaces or garages.
G. WARNING - USE ONLY METAL DUCT WORK.
H. Install this ventilator in accordance with all require-
ments specified by the manufacturer of your cooktop.
I. DO NOT USE THIS VENT WITH ANY SOLID-
STATE SPEED CONTROL DEVICE.