EasyManuals Logo
Home>Tomahawk>Welding System>1000

Tomahawk 1000 User Manual

Tomahawk 1000
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
B-11
OPERATION
B-11
MACHINE INTERFACE
The TOMAHAWK™ 1000 comes standard with a
machine interface. Interface signals provided include:
arc start, arc initiated, and arc voltage. These signals
are accessible through the 14 pin connector on the
case front.
ARC START:
The Arc Start circuit allows for triggering of the power
source to commence cutting. This circuit can be
accessed through pins K and M of the 14 pin connec-
tor. The circuit has a 15 VDC nominal open circuit
voltage and requires a dry contact closure to activate.
ARC INITIATED:
The Arc Initiated circuit provides information as to
when a cutting arc has transferred to the work piece.
This circuit can be accessed through pins I and J of
the 14 pin connector. The circuit provides a dry con-
tact closure when the arc has transferred. Input to this
circuit should be limited to 0.3 A for either 120VAC or
30VDC.
ARC VOLTAGE:
The Arc Voltage circuit can be used for activating a
torch height control. This circuit can be accessed
through pins D and G of the 14 pin connector. The
circuit provides full electrode to work arc voltage (no
voltage divider, 270VDC maximum).
Users wishing to utilize the Machine Interface can
order a K867 Universal Adapter (please adhere to the
pin locations stated above) or manufacture a 14 pin
connector cable assembly.
TOMAHAWK™ 1000
14-PIN BOX RECEPTACLE, FRONT VIEW
J
I
H
N
G
F
E
D
C
L
Arc Start
Arc Voltage
Arc Initiated
M
K

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tomahawk 1000 and is the answer not in the manual?

Tomahawk 1000 Specifications

General IconGeneral
BrandTomahawk
Model1000
CategoryWelding System
LanguageEnglish