TOPVERT S1 Series
E-
15
1
FWD/REV terminals act by level
trigger
0 (Factory Reserved)
Bit 4
1 (Factory Reserved)
Pr2-08
UP/DOWN command rate
0.011.00Hz/msec (101000Hz/sec) 0.01
Pr2-09
Digital Input terminal
debounce time
0.00130.000 Sec 0.005
00000~007FF
Pr2-10
Polarity of Digital Input
terminals
(0=Close circuit enable 1=Open circuit enable)
h00000
Pr2-11
Target count value
065500 0
Pr2-12
Pre warn count value
065500 0
Pr2-13
Digital pulse output gain
1~20 1
Pr2-14
Pre-set arrival frequency 1
0.00600.00 Hz
60.00/50.00
Pr2-15
Pre-set arrival frequency 1
bandwidth
0.00600.00 Hz
2.00
Pr2-16
Pre-set arrival frequency 2
0.00600.00 Hz
60.00/50.00
Pr2-17
Pre-set arrival frequency 2
bandwidth
0.00600.00 Hz
2.00
Pr2-18
Polarity of Digital output
terminals
00000~0003F h00000
Pr2-19
Delay time of Digital output
terminals
0.000~60.000 Sec 0.003
Pr2-20
{Pr2-19}
Multi-Function Digital output
1- Relay 1
0: No definition
11
Pr2-21
{Pr2-20}
(Factory Reserved)
1: Drive in run
1
Pr2-22
{Pr2-21}
(Factory Reserved)
2: Master frequency attained 1
(Both Forward and Reverse)
5
Pr2-23
{Pr2-22}
(Factory Reserved)
3: Master frequency attained 2
(Both Forward and Reverse)
Pr2-24 (Factory Reserved)
4: Pre-set speed attained 1
(Both Forward and Reverse)
9
5: Pre-set speed attained 1
(Forward only)
0
6: Pre-set speed attained 2
(Both Forward and Reverse)
7 : Pre-set speed attained 2
(Forward only)
8: Drive in decel
9: Drive ready for operate
10: Low voltage alarm (LU, LUr)
11: Fault Indication
12: Base block (B.B.) Indication
13: Zero Speed (including shutdown)
14: Zero speed (while in run)
15: Terminal count value attained
16: Pre warn count value attained
17: PLC Run running
18: PLC Run paused
19: A step of PLC Run completed
20: PLC Run completed
21: OH1 pre–warning indication
22: Dwell Accel/Decel in execution
23: External operation mode indication
24: Over-torque 1 (ot1)
25: (Factory Reserved)
26: Software brake output (MO1 only)
27: Auxiliary Motor no. 1
28: Auxiliary Motor no. 2
Pr2-25 (Factory Reserved)
29: Auxiliary Motor no. 3
0