6. CONTROL BLOCK DIAGRAM
Infrared Rays Signal Receiver
Functions
ECONO.
Louver Direction Setting
Louver AUTO Swing
OFF TIMER Setting
ON TIMER Setting
Fan Speed Selection
Thermo. Setting
Operation Mode Selection
AUTO, COOL, DRY, FAN ONLY
Operation (START/STOP)
Louver DriverRelay Driver
Clock Frequency
Oscillator Circuit
Heat Exchanger Sensor
Infrared
Rays
Initializing Circuit
C. P. U
Indoor Unit Control Panel
AC 220-240V
50Hz
AC 220V
50Hz
(RAS-07YKX-T, 10YKX-T only)
Remote Control
Operation
Display
Timer
Display
ECONO.
Sign Display
FAN-ONLY
Sign Display
Indoor
Fan Motor
Louver
ON/OFF Signal
Compressor, Outdoor Fan
ON/OFF Signal
Louver
Motor
Compressor
RY02
RY01
Noise Filter
Power Supply
Circuit
Outdoor Fan Motor
Relay
Thermo. Sensor
Louver Control
3-minute Delay at Restart for Compressor
Motor Revolution Control
Processing
(Temperature Processing)
Timer
Relay