1. Introduction
Thank you for your purchase of our industrial inverter “TOSVERT VF-A7/P7”.
This manual gives explanations of parameters “H, H, H” for the VF-A7/P7 inverter.
2. Functions
In the case the inverter is applied to lifting machines (crane, hoist, etc.), these parameters are used for
cooperation with the mechanical brake operation (H) and load falling prevention in winding up/down
operation (H, H).
3. Related parameters
Vector control
Title
Commu-
nication
No
Function Adjustment range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
Torque
control
Position
control
V/f
Constant
H
0451 Torque limit mode
0: Standard,
1: without speed
cooperation
−
0 Enabled ●/●− − ●
H
0452
Continuous stall trip
detection
time during power running
0.0〜1.0 [s]
0.01/0.01
0.0 Enabled ●/●− − ●
H
0453
Stall prevention during
regeneration
0: Stall
1: Stall is prevented
−
0 Enabled ●/●− − ●
Sensorless vector/vector with sensor (
●
: Valid,−: Invalid)