18-BC95D1-5E-EN
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
IMPORTANTThis Document is customer property and is to remain with this unit. Please return to service informa-
tion pack upon completion of work.
Heat Pumps
4TWR4
These instructions do not cover all variations in systems or provide for every possible contingency to be met in connection with
the installation. Should further information be desired or should particular problems arise which are not covered sufficiently for the
purchaser’s purposes, the matter should be referred to your installing dealer or local distributor.
Note: The manufacturer recommends installing only approved matched indoor and outdoor systems. All of the manufacture’s split
systems are AHRI rated only with TXV/EEV indoor systems. Some of the benefits of installing approved matched indoor and out-
door split systems are maximum efficiency, optimum performance and the best overall system reliability.
Installation and Operation Manual
Table of Contents
Section 1. Safety ..................................................................................... 2
Section 2. Unit Location Considerations ............................................. 4
Section 3. Unit Preparation .................................................................... 5
Section 4. Setting the Unit ..................................................................... 5
Section 5. Refrigerant Line Considerations ......................................... 5
Section 6. Refrigerant Line Routing ..................................................... 6
Section 7. Refrigerant Line Brazing ...................................................... 8
Section 8. Refrigerant Line Leak Check ............................................... 8
Section 9. Evacuation ............................................................................ 9
Section 10. Service Valves .................................................................... 9
Section 11. Electrical - Low Voltage ................................................... 10
Section 12. Electrical - High Voltage .................................................. 11
Section 13. Start Up .............................................................................. 12
Section 14. System Charge Adjustment ............................................. 12
Section 15. Checkout Procedures ...................................................... 16
Section 16. Defrost Control ................................................................. 17
Section 17. Troubleshooting ............................................................... 20
Section 18. Wiring Diagrams ............................................................... 22
Section 19. Pressure Curves ............................................................... 25
Section 20. Refrigerant Circuit ............................................................ 30
Question and Answer IconNeed help?

Do you have a question about the Trane 4TWR4036N and is the answer not in the manual?

Summary

Section 1. Safety

Electrical and Voltage Safety

Warnings about live electrical components, hazardous voltage, and grounding requirements.

Refrigerant and Oil Handling Safety

Precautions for R-410A refrigerant, POE oil, service valves, and hot surfaces.

Section 5. Refrigerant Line Considerations

Section 7. Refrigerant Line Brazing

Brazing Procedures

Step-by-step instructions for brazing refrigerant lines to service valves.

Section 8. Refrigerant Line Leak Check

Leak Detection Methods

Procedure for pressurizing lines and checking for leaks using a soapy solution.

Section 9. Evacuation

Section 11. Electrical - Low Voltage

Low Voltage Wiring Diagrams

Diagrams and specifications for low voltage wiring, including wire length limits.

Section 12. Electrical - High Voltage

Section 13. System Start Up

System Start Up Procedures

Step-by-step guide for initial system startup after installation.

Section 14. System Charge Adjustment

Subcooling Charging Method

Method for charging the system using subcooling, with correction tables for line length and lift.

Charging Chart and Adjustments

Using the R-410A charging chart to determine final subcooling and adjust refrigerant level.

Section 15. Checkout Procedures

Section 16. Defrost Control

Section 17. Troubleshooting

Compressor Start Troubleshooting

Flowchart for diagnosing compressor start failures, including contactor and voltage checks.

Compressor Not Running Troubleshooting

Flowchart for diagnosing compressor failures, including voltage, overload, and start component checks.

Section 18. Wiring Diagrams

Summary

Section 1. Safety

Electrical and Voltage Safety

Warnings about live electrical components, hazardous voltage, and grounding requirements.

Refrigerant and Oil Handling Safety

Precautions for R-410A refrigerant, POE oil, service valves, and hot surfaces.

Section 5. Refrigerant Line Considerations

Section 7. Refrigerant Line Brazing

Brazing Procedures

Step-by-step instructions for brazing refrigerant lines to service valves.

Section 8. Refrigerant Line Leak Check

Leak Detection Methods

Procedure for pressurizing lines and checking for leaks using a soapy solution.

Section 9. Evacuation

Section 11. Electrical - Low Voltage

Low Voltage Wiring Diagrams

Diagrams and specifications for low voltage wiring, including wire length limits.

Section 12. Electrical - High Voltage

Section 13. System Start Up

System Start Up Procedures

Step-by-step guide for initial system startup after installation.

Section 14. System Charge Adjustment

Subcooling Charging Method

Method for charging the system using subcooling, with correction tables for line length and lift.

Charging Chart and Adjustments

Using the R-410A charging chart to determine final subcooling and adjust refrigerant level.

Section 15. Checkout Procedures

Section 16. Defrost Control

Section 17. Troubleshooting

Compressor Start Troubleshooting

Flowchart for diagnosing compressor start failures, including contactor and voltage checks.

Compressor Not Running Troubleshooting

Flowchart for diagnosing compressor failures, including voltage, overload, and start component checks.

Section 18. Wiring Diagrams

Overview

This document outlines the installation and operation procedures for Trane 4TWR4 series heat pumps. It is intended for individuals with adequate electrical and mechanical experience, emphasizing compliance with national, state, and local codes. The manual stresses the importance of proper installation to ensure optimal performance, efficiency, and system reliability, particularly when using AHRI-rated matched indoor and outdoor systems with TXV/EEV indoor systems.

Function Description

The Trane 4TWR4 heat pump is designed to provide both heating and cooling for residential and commercial applications. It utilizes R-410A refrigerant, which operates at higher pressures than R-22, necessitating the use of R-410A approved service equipment. The unit's operation involves a refrigerant circuit that can be reversed for heating or cooling modes. A key component is the demand defrost control, which measures outdoor ambient and coil temperatures to determine the need for defrost cycles, optimizing heating capacity and efficiency in colder climates. The system also incorporates various safety features, including high and low-pressure cutouts, and internal overload protection for the compressor.

Usage Features

The heat pump is designed for ease of installation and operation, though it requires professional handling due to the nature of its refrigerant and electrical components. Key usage features include:

  • Refrigerant Management: The system uses R-410A refrigerant and POE oil, which is hygroscopic. This means the system should remain sealed whenever possible to prevent moisture absorption. Specific instructions are provided for brazing refrigerant lines, leak checking, and evacuation to ensure a dry and leak-free system. The manual details how to open service valves safely to prevent abrupt release of system charge.
  • Electrical Connections: Comprehensive instructions are given for both low and high voltage electrical hook-ups, including maximum wire lengths for low voltage wiring and the requirement for a separate disconnect switch for high voltage. Grounding is mandatory for all electrical components.
  • System Start-Up: A step-by-step start-up procedure is provided, including waiting periods for compressor crankcase heaters if applicable, to ensure a smooth and safe initial operation.
  • Charge Adjustment: The manual details the subcooling charging method for cooling mode (above 55°F outdoor temperature) and the weigh-in method for heating mode (below 55°F outdoor temperature). This ensures the system is accurately charged for optimal performance across different ambient conditions. Charts are provided to determine the correct subcooling values based on line length and lift.
  • Defrost Control: The unit features a selectable defrost termination temperature (47°F or 70°F) to adapt to varying climate conditions. The defrost control board includes diagnostic LEDs to indicate normal operation or fault conditions, aiding in troubleshooting. Forced defrost can be initiated for testing or servicing purposes.
  • Troubleshooting: Flowcharts are included to guide technicians through troubleshooting common issues such as compressor failure to start and problems with outdoor TXV/heating mode. These charts help diagnose electrical issues, refrigerant problems, and component failures.

Maintenance Features

Regular maintenance is crucial for the longevity and efficient operation of the Trane 4TWR4 heat pump. The manual highlights several maintenance-related aspects:

  • Refrigerant Line Integrity: Emphasizes ensuring all refrigerant line joints are brazed, not soldered, and that lines are free of leaks, acid, and oil, especially when reusing existing lines. Proper insulation of vapor lines and isolation from structural elements are also critical to prevent noise and vibration transmission.
  • Drier Replacement: Advises changing driers whenever the system is opened for component replacement to maintain refrigerant purity.
  • Component Inspection: Recommends a final unit inspection to ensure factory tubing has not shifted during shipment and that all wiring connections are tight and properly secured. This prevents rubbing and potential electrical issues.
  • Airflow and Drainage: Stresses the importance of ensuring indoor coil drain lines drain freely and that supply registers and return grilles are open and unobstructed. The outdoor unit's location should allow for adequate airflow and prevent obstruction of drain holes in the basepan, especially in cold climates where snow and ice accumulation can be an issue.
  • Filter Maintenance: Reminds installers to ensure a return air filter is installed and to check that the correct airflow setting is used for the indoor blower motor.
  • Fault Detection: The defrost control board's LED fault codes provide immediate diagnostic information, simplifying troubleshooting and maintenance. These codes indicate issues such as sensor failures, low pressure switch open, and various lockout conditions, guiding technicians to specific problem areas.
  • Sensor Testing: Instructions are provided for testing temperature sensors by measuring resistance and comparing it to a thermistor table, allowing for quick verification of sensor functionality.

The manual serves as a comprehensive guide for professional installers and service technicians, ensuring that the Trane 4TWR4 heat pump is installed, operated, and maintained to the highest standards.

Trane 4TWR4036N Specifications

General IconGeneral
Model4TWR4036N
TypeHeat Pump
SEER Rating16
RefrigerantR-410A
Voltage208/230V
Phase1
Cooling Capacity36000 BTU/h
Heating Capacity36000 BTU/h
Compressor TypeScroll
Operating Temperature Range (Heating)-5°F to 65°F