General Information
Model Number Description
All products are identified by a multiple character model number listed on the unit nameplate. An explanation of the alphanumeric identifi-
cation code is provided below. Its use can define the unit's specific components, type of application, i.e. CV or VAV, for a particular unit.
When ordering replacement parts or requesting service, be sure to refer to the specific model number, serial number, and DL number (if
applicable) stamped on the unit nameplate.
Sample Model No.: S X H F - *20 4 0 A 1 0 A 1 5 B 1 D 0 1 A,R,L,etc.
Digit No.: 1 2 3 4 5,6,7 8 9 10 11 12 13 14 15 16 17 18 19 20 21+
Digit 1 - Unit Type Digit 10 - Design Sequence Digit 17 - System Control
S = Self-Contained 3 = Disconnect Redesi
g
n 1 = CV Control
(
Zone Control
)
Note: Sequence may be any letter
2 = VAV-(S/A Temp Control
Digit 2 - Unit Function A thru Z, or any digit 1 thru 9.
without Inlet Guide Vanes)
A = DX Coolin
g
, No Heat 3 = VAV-
(
S/A Tem
p
Control
E = DX Cooling, Electric Heat
Digit 11 - Exhaust Option
with Inlet Guide Vanes)
F = DX Coolin
g
, Natural Gas Heat 0 = None 4 = S
p
ace Pressure Control with Exhaust VFD
L = DX Coolin
g
, Hot Water Heat 1 = Barometric without B
yp
ass
S = DX Coolin
g
, Steam Heat 2 = 100% - 1.5 HP* 5 = S
p
ace Pressure Control with Exhaust VFD
X = DX Coolin
, Extended Casin
s 3 = 100% - 3 HP* and B
yp
ass
# = DX Coolin
g
, Pro
p
ane Gas Heat 4 = 100% - 5 HP* 6 = VAV Su
pp
l
y
Air Tem
p
erature Control
5 = 100% - 7.5 HP* with VFD w/o B
yp
ass
Digit 3 - Unit Airflow
6 = 100% - 10 HP* 7 = VAV Supply Air Temperature Control
H = Sin
g
le-Zone 7 = 100% - 15 HP* with VFD and B
yp
ass
8 = 100% - 20 HP* 8 = Su
pp
l
y
and Exhaust Fan with VFD
Digit 4 - Development Sequence A = 50% - 1.5 HP without Bypass
F = Sixth B = 50% - 3 HP 9 = Su
pp
l
y
and Exhaust Fan with VFD
C = 50% - 5 HP and B
yp
ass
Digits 5, 6, 7 - Nominal Capacity
D = 50% - 7.5 HP
*20 = 20 Tons *55 = 55 Tons E = 100% - 1.5 HP**
Digit 18 - Accessory Panel
*25 = 25 Tons *60 = 60 Tons F = 100% - 3 HP** 0 = None
*30 = 30 Tons *70 = 70 Tons G = 100% - 5 HP** A = BAYSENS008*
*40 = 40 Tons *75 = 75 Tons H = 100% - 7.5 HP** B = BAYSENS010*
*50 = 50 Tons J = 100% - 10 HP** C = BAYSENS013*
K = 100% - 15 HP** D = BAYSENS014*
Digit 8 - Power Supply
L = 100% - 20 HP** E = BAYSENS019*
4 = 460/60/3 XL # = 50% w/ Statitrac F = BAYSENS020*
5 = 575/60/3 XL * w/Statitrac G = BAYSENS021*
E = 200/60/3 XL ** w/o Statitrac
(
CV onl
y)
F = 230/60/3 XL Digit 19 - Ambient Control
Note: SEHF units (unit with Digit 12 - Exhaust Fan Drive 0 = Standard
electric heat) utilizing 208V or
0 = None 8 = 800 PRM 1 = 0 Degree Fahrenheit
230V require dual power source.
4 = 400 RPM 9 = 900 RPM
5 = 500 RPM A = 1000 RPM
Digit 20 - Agency Approval
Digit 9 - Heating Capacity
6 = 600 RPM B = 1100 RPM 0 = None (UL Gas Heater, see note)
7 = 700 RPM 1 = UL
Note: When the second digit
2 = CSA
calls for "F" (Gas Heat), the Digit 13 - Filter Type Note: Includes UL clsssified gas heating
following values apply:
A = Throwaway
section only when second digit of
Additionally, please note G and
B = Cleanable Wire Mesh
Model No. is a "F".
M available ONLY on 50 Ton
C = High-Efficiency Throwaway
models and above.
D = Bag with Prefilters
Digits 21 - 38 - Miscellaneous
H = Hi
g
h Heat - 2 Sta
g
eE = Cartrid
g
e with Prefilters 21 A = Unit Disconnect Switch
L = Low Heat - 2 Stage F = No Filters (T/A Rack Only) 22 B = Hot Gas Bypass
0 = No Heat G = No Filters
(
Ba
g
/Cart. Rack Onl
y)
23 C = Economizer Control w/Com
p
arative
J = Limited Modulatin
g
Hi
g
h Heat Enthal
py
G = Limited Modulating Low Heat
Digit 14 - Supply Fan Horsepower
23 Z = Economizer Control w/Reference
P = Full Modulatin
g
Hi
g
h Heat 1 = 3.0 HP 6 = 20.0 HP Enthal
py
M = Full Modulating Low Heat 2 = 5.0 HP 7 = 25.0 HP 23 W = Economizer Control w/Dry Bulb
Note: When the second digit
3 = 7.5 HP 8 = 30.0 HP 23 O = None W/O Economize
r
calls for "E" (electric heat), the
4 = 10.0 HP 9 = 40.0 HP
1
24 E = Low Leak Fresh Air Dampers
following values apply:
5 = 15.0 HP 25 F = High Duct Temperature Thermostat
D = 30 KW R = 130 KW 26 G = Hi
g
h Ca
p
acit
y
Eva
p
orator Coil
H = 50 KW U = 150 KW
Digit 15 - Supply Fan Drive
H = Hi Cap Evap Coil & Hi Eff Cond Coil (25,30,50 Ton only)
L = 70 KW V = 170 KW 5 = 500 RPM B = 1100 RPM 27 H = Co
pp
er Fins
(
Cond. onl
y)
N = 90 KW W = 190 KW 6 = 600 RPM C = 1200 RPM 28 K = Generic B.A.S. Module
Q = 110 KW 7 = 700 RPM D = 1300 RPM 29 L = Hi
gh-Efficiency Motors (Supply & Exhaust)
Note: When the second digit calls
8 = 800 RPM E = 1400 RPM 30 M = Remote Human Interface
"L" (Hot Water) or "S" (Steam)
9 = 900 RPM F = 1500 RPM 31 N = Ventilation Override Module
Heat, one of the following valve
A = 1000 RPM G = 1600 RPM 32 R = Extended Grease Lines
size values must be in Digit 9: 33 T = Access Doors
High Heat Coil: 1 = 50", 2 = .75", Digit 16 - Fresh Air Section 34 V = Interprocessor Communications Bridge
3 = 1", 4 = 1.25", 5 = 1.5", 6 = 2". A = No Fresh Air 35 0 = No communication module
Low Heat Coil: A = .50", B = .75", B = 0-25% Manual 35 Y = Trane Communication Interface Module
C = 1", D = 1.25", E = 1.5", F = 2". D = 0-100% Economizer 35 7 = LonTalkĀ® Communication Interface Module
36 8 = S
pring Isolators
37 6 = Factor
y-Powered 15A GFI Convenience
1. Available as standard 460 volt onl
y for 70 and 75 ton models Outlet
2. * in di
git 5 indicates C or F 38 0 = None

Table of Contents

Other manuals for Trane IntelliPak

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane IntelliPak and is the answer not in the manual?

Trane IntelliPak Specifications

General IconGeneral
BrandTrane
ModelIntelliPak
CategoryAir Conditioner
LanguageEnglish

Related product manuals