EasyManuals Logo

Trane NTXMMX30A132AA User Manual

Trane NTXMMX30A132AA
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #70 background imageLoading...
Page #70 background image
70
ACTUATOR CONTROL
9
NTXMMX20A122AA NTXMMX24A132AA NTXMMX30A132AA NTXMMX36A142AA
NTXMMX42A152AA
NTXMPH20A122AA NTXMPH24A132AA NTXMPH30A132AA
Relation between main sensor and actuator
Sensor Purpose
Actuator
Compressor LEV
Outdoor
fan motor
4-way valve
2-way solenoid
valve
Defrost
heater
(NTXMMX42A152AA
NTXMPH20A122AA
NTXMPH24A132AA
NTXMPH30A132AA)
(NTXMPH20A122AA
NTXMPH24A132AA
NTXMPH30A132AA)
Discharge temperature
thermistor
Protection
Indoor coil temperature
thermistor
Cooling: Coil frost
prevention
Heating: High pres-
sure protection
Defrost thermistor Heating: Defrosting
Fin temperature
thermistor
Protection
Ambient temperature
thermistor
Control/Protection
Heating: Defrosting
(Heater)
Outdoor heat exchanger
temperature thermistor
Cooling: Control/
Protection
Capacity code Control
OBHT702