Technical Data
FWD 08 12 20 30 45
Power supply (V/Ph/Hz) 230/1/50
Capacities
Cooling capacity on water (1) (kW) 5,2 8,3 15 18,8 30,1
Heating capacity on water (2) (kW) 6,3 11,9 18,9 20,9 38,2
Fan motor (type) 2 x direct drive centrifugal
Fan power input (3) (kW) 0,23 0,46 0,65 1,04 1,51
Current amps (3) (A) 1,1 2,2 3,1 4,7 5,5
Start-up amps (A) 3,2 5,5 9,3 14,1 16,5
Air flow
minimum (m
3
/h) 490 980 1400 1800 2700
nominal (m
3
/h) 820 1650 2300 3000 4500
maximum (m
3
/h) 980 1970 2600 3600 5400
Main coil
Water entering/leaving connections (type) ISO R7 rotating female
(Dia) 3/4" 3/4" 1 1/2" 1 1/2" 1 1/2"
Electric heater (accessory for blower only)
Electric power supply (V/Ph/Hz) 230/1/50 230/1/50 or 400/3/50 400/3/50 400/3/50 400/3/50
Heating capacity (kW) 2/4 8 10 12 12
Hot water coil (accessory for blower only)
Heating capacity (4) (kW) 6,3 12 17,4 22,4 34,5
G2 filter (filter box accessory)
Quantity 2 2 2 2 2
Dimensions ( LxWxth) (mm) 386x221x8 486x271x8 586x321x8 586*421*8 586*621*8
G4 filter (filter box accessory)
Quantity - 2 2 2 2
Dimensions ( LxWxth) (mm) - 486x264x48 586x314x48 586*414*48 586*614*48
Condensate pump (accessory) (type) Centrifugal
Water flow - lift height (l/h - mm) 24 - 500
Not available for FWD30 and FWD45
Sound level (L/M/H speed)
Sound pressure level (5) (dB(A)) 36/40/43 38/41/44 46/50/53 47/52/57 47/52/58
Sound power level (5) (dB(A)) 46/50/53 48/51/54 56/60/63 57/62/67 57/62/68
Unit dimensions
Width x Depth (mm) 890 x 600 1090 x 710 1290 x 820 1290 x 970 1290 x 1090
Height (mm) 250 300 350 450 650
Shipped unit dimensions
Width x Depth (mm) 933 x 644 1133 x 754 1333 x 864 1333 x 1008 1333*1133
Height (mm) 260 310 360 460 660
Weight (kg) 32 46 61 76 118
Colour galvanised steel
Recommended fuse size
Unit alone (aM/gI) (A) 8/16 8/16 8/16 8/25 8/25
Unit with electric heater (gI) (A) 16 (2kW),25 (4kW) 40 (230V),3*16 (400V) 3*20 3*25 3*25
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.
Heat exchanger operating limits:
FWD:
*water temperature: max 100° C
*absolute service pressure: min 1 bar/max 11 bars
Accessories - Hot water coil:
*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars
General information
Foreword
These instructions are given as a guide to good practice in the installation, operation and periodic maintenance by
the user of TRACER CH535 chiller controller.
They do not contain the full service procedures necessary for the continued successful operation of this equipment.
The services of a qualified service technician should be employed, through the medium of a maintenance contract
with a reputable service company.
Warranty
Warranty is based on the general terms and conditions of the constructor. The warranty is void if the equipment is
modified or repaired without the written approval of the constructor, if the operating limits are exceeded, or if the
control system or the electrical wiring is modified. Damage due to misuse, lack of maintenance, or failure to comply
with the manufacturers instructions, is not covered by the warranty obligation. If the user does not conform to the
rules of “Maintenance”, it may entail cancellation of warranty and liabilities by the constructor.
Reception
When the unit arrives on site, check it has not been damaged in any way during transport. If damage is observed, or
even merely suspected, notify the carrier within 24 hours by registered letter. Notify the local Trane Sales office at the
same time. The unit should be totally inspected within 3 days of delivery. If damage is observed, notify the last carrier
by registered letter and notify the local sales office.
General information
About this manual
Cautions appear at appropriate places in this instruction manual. Your personal safety and the proper operation of
this machine require that you follow them carefully. The constructor assumes no liability for installations or servicing
performed by unqualified personnel.

Other manuals for Trane Tracer CH535

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane Tracer CH535 and is the answer not in the manual?

Trane Tracer CH535 Specifications

General IconGeneral
BrandTrane
ModelTracer CH535
CategoryController
LanguageEnglish

Related product manuals