EasyManuals Logo
Home>Trane>Furnace>*UH2B080A9V3VA

Trane *UH2B080A9V3VA Service Facts

Trane *UH2B080A9V3VA
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Service Facts
© 2011 Trane All Rights Reserved
NOTICE: The manufacturer has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice.
PRODUCT SPECIFICATIONS
1
MODEL
TYPE
RATINGS
2
1st Stage Input BTUH
1st Stage Capacity BTUH (ICS)
3
2nd Stage Input BTUH
2nd Stage Capacity BTUH (ICS)
3
AFUE
Temp. rise (Min.-Max.) °F.
BLOWER DRIVE
Diameter - Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts / Ph / Hz
COMBUSTION FAN - Type
Drive - No. Speeds
Motor HP - RPM
Volts / Ph / Hz
FLA
FILTER — Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
VENT — Size (in.)
HEAT EXCHANGER
Type -Fired
-Unfired
Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICE
Type
BURNERS — Type
Number
POWER CONN. — V / Ph / Hz
4
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONS
Crated (In.)
WEIGHT
Shipping (Lbs.) / Net (Lbs)
*UH2B080A9V3VA
Upflow / Horizontal
52,000
50.440
80,000
77,600
97
35 - 65
DIRECT
10 x 8
1
Variable
See Fan Performance Table
1/2
Variable
115/1/60
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
Yes
High Velocity
1 - 17x25 - 1 in.
2 Round
Aluminized Steel - Type I
20
4 — 45
4 — 56
Redundant - Two Stage
Hot Surface Igniter
Multiport Inshot
4
115/1/60
11.1
15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
168 / 156
Gas Furnace – Var. Speed Blower –
Var. Speed Inducer – Two Stage Heat –
Direct Vent
Models: * - First letter may be “A” or “T”
IMPORTANT — This document contains a wiring diagram and service information. This is customer property and is to
remain with this unit. Please return to service information pack upon completion of work.
DISCONNECT POWER BEFORE SERVICING
WARNING
*UH2B060A9V3VA
Upflow / Horizontal
39,000
37,830
60,000
58,200
97
35 - 65
DIRECT
10 x 8
1
Variable
See Fan Performance Table
1/2
Variable
115/1/60
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
Yes
High Velocity
1 - 17x25 - 1 in.
2 Round
Aluminized Steel - Type I
20
3 — 45
3 — 56
Redundant - Two Stage
Hot Surface Igniter
Multiport Inshot
3
115/1/60
11.1
15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
158 / 146
*UH2C100A9V4VA
Upflow / Horizontal
65,000
62,855
100,000
96,700
97
35 - 65
DIRECT
10 x 10
1
Variable
See Fan Performance Table
3/4
Variable
115/1/60
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
Yes
High Velocity
1 - 20x25 - 1 in.
3 Round
Aluminized Steel - Type I
20
5 — 45
5 — 56
Redundant - Two Stage
Hot Surface Igniter
Multiport Inshot
5
115/1/60
13.5
20
1/2
H x W x D
41-3/4 x 23 x 30-1/2
197 / 185
1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3.
2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level.
For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3 Based on U.S. government standard tests.
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
AVAILABLE IN FRENCH CANADIAN (FC)
UH2-SF-1G
X343070P08
*UH2B060A9V3VA
*UH2B080A9V3VA
*UH2B080A9V4VA
*UH2C100A9V4VA
*UH2C100A9V5VA
*UH2D120A9V5VA
*DH2B060A9V3VA
*DH2B080A9V3VA
*DH2B080A9V4VA
*DH2C100A9V4VA
*DH2D120A9V5VA
*UH2B080A9V4VA
Upflow / Horizontal
52,000
50,440
80,000
77,600
97
35 - 65
DIRECT
11 x 8
1
Variable
See Fan Performance Table
3/4
Variable
115/1/60
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
Yes
High Velocity
1 - 17x25 - 1 in.
2 Round
Aluminized Steel - Type I
20
4 — 45
4 — 56
Redundant - Two Stage
Hot Surface Igniter
Multiport Inshot
4
115/1/60
13.5
20
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
170 / 158

Other manuals for Trane *UH2B080A9V3VA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane *UH2B080A9V3VA and is the answer not in the manual?

Trane *UH2B080A9V3VA Specifications

General IconGeneral
BrandTrane
Model*UH2B080A9V3VA
CategoryFurnace
LanguageEnglish

Related product manuals