EasyManuals Logo
Home>Trane>Heat Pump>Variable Speed ComfortLink II 4TTV8048A1000B

Trane Variable Speed ComfortLink II 4TTV8048A1000B User Manual

Trane Variable Speed ComfortLink II 4TTV8048A1000B
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background imageLoading...
Page #25 background image
18-BC92D1-1F-EN
25
Communicating Display Assembly (CDA)
1. External shut down
(Load Shed)
2. Min. Airflow
3. Blower on/off delays
4. Custom Airflow
5. PFC (Power Factor
Correction)
1. FRC DFT (Forced Defrost)
2. EEV Test
3. Evacuation
4. Drive Diagnostic Test
5. OD Fan Test
TECHNICIAN MENUS
SYSTEM STATUS
XXXXXXXXXXXXXXXX
NAVIGATION
• To enter and exit Technician Menus, press the Up/Down buttons
sim ultaneously for 5 seconds.
• To return to the Hom e Screen, press the Up/Down buttons
sim ultaneously for 5 seconds.
• To return to the top level of any menu, press the Left/Right buttons
sim ultaneously for 5 seconds.
• After five minutes of inactivity in the Technician Menu section, the
Hom e Screen will be displayed. Pressing the Enter button for
5 seconds will increase this time to 20 m inutes.
ALERT HISTORY
MENU
ALERT MENU
CONFIG MENU
CONTROL MENU
MONITOR MENU
The Monitor Menu
displays inform ation
on System status,
Drive stats and the
System Tachom eter.
The Alert History
menu displays alerts
sto red over time. Note
that clearing Alert
History will also clear
Active Alerts.
The Alert Menu
displays active alerts.
The Configuration
Menu is where
System param eters
and options are set
and reported.
The Control Menu
contains a selection of
unit function tests that
are used to verify
operation.
Scan to see an
overview video
about the CDA
NNoottee:: See the Service Facts found in the control box of
the outdoor unit for more information.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane Variable Speed ComfortLink II 4TTV8048A1000B and is the answer not in the manual?

Trane Variable Speed ComfortLink II 4TTV8048A1000B Specifications

General IconGeneral
BrandTrane
ModelVariable Speed ComfortLink II 4TTV8048A1000B
CategoryHeat Pump
LanguageEnglish

Related product manuals