49
6.4 Sensor
This option is used to calibrate the selected sensor. We recommend calibrate the sensor before printing when changing the media.
Item
Description
Default
Auto Calibration
Set the media sensor type and calibrate the selected sensor automatically.
N/A
Manual Calibration
In case Auto Calibration does not work, please use “Manual” function to set the paper length and
gap/bline size to complete the calibration setting.
N/A
Threshold Detect
Set sensor sensitivity in fixed or auto.
Auto
Maximum Length
Set the maximum length for label calibration.
254 mm
BMark Transmitter
This option is used to setupper or lower black mark sensor as the main transmitter.
Back
side
Advanced
Set the minimum paper length and maximum gap/bline length for auto-calibratIon.
0 mm
Menu Sensor
Auto Calibration
Gap
Black Mark
Continuous
Preprint
Manual
Calibration
Standard
Gap
Black Mark
Continuous
Threshold Detect
Auto
Fixed
Maximum Length
BMark
Transmitter
Advanced
Min. Paper
Max.
Gap/Mark

Other manuals for TSC MH241 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TSC MH241 Series and is the answer not in the manual?

TSC MH241 Series Specifications

General IconGeneral
BrandTSC
ModelMH241 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals