2018-01-02
2900 5262
SENSE COMBI PURE Quick-Start Tip Sheet
This page to be used in conjuction with Tylo Full Manual included
CONNECTION/WIRING DIAGRAM
TAB 208 V 1 Phase 240 V 1 Phase
Model Amperage
Amps
Output
kW
Wire Size
AWG
Amperage
Amps
Output
kW
Wire Size
AWG
Sense Combi-U 7 26
5.3
10 30
7.0
8
Sense Combi-U 8 30
6.3
8 35
8.3
8
Note: Heating elements do not change for voltage changes. The heater output will change
based on the voltage applied to heater. Most North American homes are 240v.
10
1415
12
13
11
14
RJ10 4P4C
3 x 14 AWG
RJ10 4P4C
RJ10 4P4C
RJ10 4P4C
ax 300 feet - Combi Pure
*
**
BB4140
12
6789
34 5
120 V~
14 AWG
Max. 6 Amp.
5.3-8.3 kW
208/240 V~
G
Connect Control cable to
jack 9 on circuit board.
Connect NTC Sensor cable
to jack 1 on circuit board.
Sensor Installation Tip
Sensor with metal tab can usually installed without cov-
er with one screw through the sensor tab directly to the
¿QLVKHGZDOO
If using Sensor Cover, you must feed the sensor wire
through the sensor holder FIRST before putting sensor
wire in the wall.
Figure 19: Wiring diagram
1. NTC Sensor - Combi Pure.
2. Ext switch (External switch Optional)
3.
Door jumper pre-installed in terminal #3.
(Door contact not required for N America)
4.-8.
N/A
9.
Pure Control
10. Heater
11. Terminal for connection of electrical cable
12. Control panel (connect to position 9)
13. Sensor - Combi Pure (connect to NTC
terminal #1)
14.
Light/terminal for connection of light.
(requires separate 120v supply)
15.
Door Contact not required for N America
16. External switch (option)
In order for control
to operate light, a
separate 120V supply
must be provided and
connected to heater
Field Connect three
copper conectors
x3