Installation Troubleshooting
Problem
Q:
Water is leaking under the unit.
Solution
A:
A water leak under the unit is most likely caused by a bad
connection in the water supply line. Make sure the water line’s
brass fitting is screwed tight to its valve and threaded correctly.
Problem
Q:
The door remains open unless it is pushed closed.
Solution
A:
The hinges should be self-closing when the door is open
approximately 8". If this is not the case, make sure the closers (at
the bottom of the hinge pin) are clean, greased and installed
correctly. Also, re-check leveling from front to back of the unit and
readjust if necessary. Make sure that pivot plate is installed
correctly.
Problem
Q:
The custom overlay door was designed to align with the rest of the
cabinet doors, but the unit has crept forward.
Solution
A:
Make sure that the electrical cord and water supply line are not
obstructing the installation.