EasyManuals Logo
Home>Ugolini>Industrial Equipment>MT micro 1

Ugolini MT micro 1 User Manual

Ugolini MT micro 1
11 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
22
MT micro
gaskets, check for improper lubrication, worn or
damaged parts. Replace parts as needed.
2 In case of noise it needs to unplug the cooler
and call for service.
3 In case of failure unplug the machine,
because unexpected start again would be
possible.
4 It needs to fix everything back in the initial
position after any repairmen, like screws and
covers.
8. 1 MAINTENANCE (TO BE CARRIED
OUT BY QUALIFIED SERVICE
PERSONNEL ONLY)
1 Monthly: remove the dust from the
condenser. To do this unplug the unit.
2 Annually: remove the panels and clean the
inside of the machine including the base, side
panels, condenser, etc.
3 Annually: Check if the auger bushings are
worn out or ovalized. If they are, replace them
with new ones.
4 Never remove the insulating jacket from
around the suction tubing of the evaporator (the
copper tubing located on the right side of gear
motor). In case the insulating jacket is missing
replace the entire parts with original spare parts
from the supplier.
5 In order to prevent any damages to the
dispenser, all plastics parts must be lubricated
only with grease supplied by the manufacturer or
with another lubricating product suitable for
polycarbonate.
ATTENTION
Condenser fins are very sharp. Use
extreme caution when cleaning.