16
Model UT33A: OPERATING MANUAL
Measurement Operation (3)
2. Set the rotary switch to V range.
3. Connect the test leads across with the object being measured.
The measured value shows on the display.
l DCV Measurement is autoranging, the Meter has an input impedance of approx.
10M. This loading effect can cause measurement errors in high impedance
circuits. If the circuit impedance is less than or equal to 10k, the error is negligible
(0.1% or less).
l When DC voltage measurement has been completed, disconnect the connection
between the testing leads and the circuit under test.
Note:

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the UNI-T UT33A and is the answer not in the manual?

UNI-T UT33A Specifications

General IconGeneral
DC Voltage Range200mV/2V/20V/200V/500V
AC Voltage Range200V/500V
DC Current Range200μA/2mA/20mA/200mA/10A
Resistance Range200Ω/2kΩ/20kΩ/200kΩ/2MΩ/20MΩ
DisplayLCD
Display Count1999
Diode TestYes
Continuity TestYes
Data HoldYes
Battery Test1.5V/9V
Battery Type9V (6F22)
Weight156g