The Model UT50A: The AC voltage measurement has
5 measurement positions on the rotary switch: 200mV,
2V, 20V, 200V and 750V
The Model UT50B/UT50C: The AC voltage measurement
has 4 measurement positions on the rotary switch: 2V,
20V, 200V and 750V
To measure AC Voltage, connect the Meter as follows:
1. Insert the red test lead into the V terminal and
the black test lead into the COM terminal.
2. Set the rotary switch to an appropriate measurement
position in V range.
3. Connect the test leads across with the object being
measured. The measured value shows on the display,
which is effective value of sine wave (mean value
response).
Note
l If the value of voltage to be measured is unknown,
use the maximum measurement position (750V) and
reduce the range step by step until a satisfactory
reading is obtained.
l The LCD displays “1” indicating the existing selected
range is overloaded, it is required to select a higher
range in order to obtain a correct reading.
l In each range, the Meter has an input impedance of
approx. 10M This loading effect can cause
measurement errors in high impedance circuits. If
the circuit impedance is less than or equal to 10k,
the error is negligible (0.1% or less).
l When AC voltage measurement has been completed,
disconnect the connection between the testing leads
and the circuit under test.
Measurement Operation(3)
Model UT50A/B/C: OPERATING MANUAL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the UNI-T UT50B and is the answer not in the manual?

UNI-T UT50B Specifications

General IconGeneral
BacklightYes
Product typeDigital multimeter
AC current range0.002 - 20 A
AC voltage range2 - 750 V
DC current range0.02 - 20 A
DC voltage range0.2 - 1000 V
Capacitance range20 - 100000 nF
Basic accuracy (DC current)±(0.8%+1)
Basic accuracy (DC voltage)±(0.5%+1)
Basic accuracy (capacitance)±(4%+3)
Temperature measurement range-40 - 1000 °C
Dimensions (WxDxH)80 x 38.3 x 165 mm
Battery voltage9 V
Weight and Dimensions IconWeight and Dimensions
Weight275 g