Measurement Operation(4)
C. DC Current Measurement (see figure 5)
Warning
Never attempt an in-circuit current measurement
where the open circuit voltage between terminals
and ground is greater than 60V DC or 30V rms.
If the fuse burns out during measurement, the Meter
may be damaged or the operator himself may be hurt.
Use proper terminals, function, and range for the
measurement. When the testing leads are connected
to the current terminals, do not parallel them across
any circuit.
The Model UT50A: The DC current measurement has
4 measurement positions on the rotary switch: 20µA,
2mA, 200mA and 20A.
The Model UT50B: The DC current measurement has
4 measurement positions on the rotary switch: 2mA,
20mA, 200mA and 20A.
The Model UT50C: The DC current measurement has
3 measurement positions on the rotary switch: 20mA,
200mA and 20A.
To measure current, do the following:
1. Turn off power to the circuit. Discharge all high-
voltage capacitors.
( figure 5)
red
black
Model UT50A/B/C: OPERATING MANUAL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the UNI-T UT50B and is the answer not in the manual?

UNI-T UT50B Specifications

General IconGeneral
BacklightYes
Product typeDigital multimeter
AC current range0.002 - 20 A
AC voltage range2 - 750 V
DC current range0.02 - 20 A
DC voltage range0.2 - 1000 V
Capacitance range20 - 100000 nF
Basic accuracy (DC current)±(0.8%+1)
Basic accuracy (DC voltage)±(0.5%+1)
Basic accuracy (capacitance)±(4%+3)
Temperature measurement range-40 - 1000 °C
Dimensions (WxDxH)80 x 38.3 x 165 mm
Battery voltage9 V
Weight and Dimensions IconWeight and Dimensions
Weight275 g