UTP3000C Series User Manual
6
Remote Control
COM setting: set computer COM portsetting as below:
Baud Rate: 9600
Calibration Bit: None
Data Bit: 8
Stop Bit: 1
RS232 Interface Definition
Communication protocol V2.0
Order Format: VSETX:NR2
1. VSET: Order Parameter
2. X: Channel
3. :Separator
4. NR2: Parameter
Order Description:
1. LOCKNR2
Function Description:Lock power supply operation panel
Example: LOCK1
Lock power supply operation panel
Example:LOCK0
Unlock power supply operation panel
2. ISETX: NR2
Function Description: Set current value
Example: ISET1:2.225
Set current value as 2.225A
3. ISETX?
Function Description: Read the set current value