UTP3000C Series User Manual
7
Example: ISET1?
Returnset current value
4. VSET<X> : <NR2>
Function Description: Set voltage value
Example: VSET1:20.50
Set voltage value as 20.50V
5. VSET<X>?
Function Description: Read voltage value
Example: VSET1?
Return set voltage value
6. IOUT<X>?
Function Description: Read current output value
Example: IOUT1?
Read the set current value
7. VOUT<X>
Function Description: Read voltage output value
Example: VOUT1?
Read the set voltage value
8. OUT<Boolean>
Function Description: Turn on/off power supply output
Boolean: 0 off; 1 on
Example: OUT1 Turn on power supply output
9. BEEP<Boolean>
Function Description: Turn on/off buzzer
Example: BEEP1 Turn on buzzer
10. STATUS?
Function Description: Read power supply output status
Contents 8 bits in the following format
Bit Item Description
0 CH1 0=CC mode, 1=CV mode
1 CH2 0=CC mode, 1=CV mode
2,3,4,5 N/A
6 Output 0=Off, 1=On
7 N/A N/A
11. *IDN?
Function Description: Return to device model & factory information
Example: *IDN?
Contents UNI-T P33XC V2.0 (manufacturer, model name)
12. RCL<NR1>
Function Description:Storage recall by pressing keys from M1-M5
13. SAV<NR1>
Function Description: Storage setting
Example: SAV1 Stores the panel setting in memory number 1
14. TRACK<NR1>