EasyManuals Logo
Home>Unitech>PDA>PA500

Unitech PA500 Programming Manual

Unitech PA500
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
- 2
1. INTRODUCTION.................................................................................................................5
1.1 How to download data from scanner....................................................................................................................... 5
1.2 COM definition for PA500............................................................................................................................................ 6
2. USI.DLL – UNITECH SCANNER INTERFACE DLL........................................................... 7
2.1. Register the application to the USI DLL .................................................................................................................. 7
2.2. Unregister the application from the USI.DLL......................................................................................................... 8
2.3. Enable / Disable Scanner............................................................................................................................................. 8
2.4. Reset Scanner................................................................................................................................................................ 8
2.5. Get error code ................................................................................................................................................................ 8
2.6. Returns the system error code.................................................................................................................................. 8
2.7. Get scan data.................................................................................................................................................................. 9
2.8. Get length of scanned data....................................................................................................................................... 10
2.9. Get Symbology name ................................................................................................................................................. 10
2.10. Clear scan data system buffer ............................................................................................................................. 11
2.11. Good read indicator................................................................................................................................................ 11
2.12. Wait for acknowledgement of the last sent command .................................................................................. 11
2.13. Save setting to profiles.......................................................................................................................................... 11
2.14. Save scanner setting into specified file............................................................................................................. 12
2.15. Change scanner setting from specified setting profile................................................................................. 12
2.16. Automatically enable scanner beam with pressing trigger key.................................................................. 12
2.17. Stop auto scanning function................................................................................................................................13
2.18. Check if auto scanning is enable ........................................................................................................................ 13
2.19. Check if Scan2Key.exe program is running or not......................................................................................... 13
2.20. Test if Scan2Key is enabled.................................................................................................................................. 13
2.21. Load/Unload Scan2Key.exe.................................................................................................................................. 13
2.22. Enable/Disable Scan2Key ..................................................................................................................................... 14
2.23. Send scanner command to decoding chip....................................................................................................... 14

Table of Contents

Other manuals for Unitech PA500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Unitech PA500 and is the answer not in the manual?

Unitech PA500 Specifications

System Memory IconSystem Memory
SDRAM64 MB
Flash ROM64 MB
Display IconDisplay
display resolution240x320 QVGA
display typeColor Transflective TFT
touch screenyes
Laser Bar Code Scanner IconLaser Bar Code Scanner
scan rate104 scans/sec ± 12 scans/sec
scan angle default47°±3°
scan angle reduced35°±3°
Power IconPower
main battery voltage3.7 V
main battery capacity2200 mAh
rechargeable time3.5 hours
Operating Environment IconOperating Environment
operating temperature32°F to 122°F (0°C to 50°C)
storage temperature-4°F to 140°F (-20°C to 60°C)
relative humidity5% ~ 95% (non-condensing)
Weight and Dimensions IconWeight and Dimensions
weight with battery and scan engineUnder 213 g
length126 mm
height23 mm

Related product manuals