5
ENG - English
h. depth/time measuring device
i. additional safety device(s)
j. voice communication system
2.3 Limitations provided by EN 250: 2014
The SCUBA unit can be comprised of separate components such as: cylinder(s), regulator(s),
pressure gauge. The SCUBAPRO regulators described in this manual can be used with
SCUBA components units certied according to regulation EU 2016/425 and EN 250:
2014 norm. The air contained in the cylinders must be compliant with the requirements
for breathable air set forth in EN 12021. The certication depth is 50 meters (164 ft). In any
event, divers must always abide by the limits set by local regulations in the dive location.
WARNING
If a SCUBA is congured for and used by more than one diver at the same time, then
it shall not be used at depths greater than 30 meters and in water temperature less
than 4°C if marked “EN250A” ,and less than 10°C If marked with “EN250A>10°C”
WARNING
Only SCUBA complying with EN250:2014 and marked “EN250A” or “EN250A>10°C”
may be used as an escape device by more than one diver at the same time
WARNING
In accordance with European standards, our regulators can only be considered
certied where all components are present, as per the original SCUBAPRO
conguration, including the low pressure hose supplied.
Any variation of the original conguration invalidates conformity to European
certication standards.
3. IMPORTANT WARNING REMINDERS
For your protection while using SCUBAPRO life support equipment, we call your attention
to the following:
1. Use the equipment according to the instructions contained in this manual and only after
having completely read and understood all instructions and warnings.
2. Use of the equipment is limited to the uses described in this manual or for applications
approved in writing by SCUBAPRO.
3. Cylinders must only be lled with atmospheric compressed air, according to the
EN 12021 norm. Should moisture be present in the cylinder, beside causing corrosion
of the cylinder, it may cause freezing and subsequent malfunction of the regulator during
dives carried out in low temperature conditions (lower than 10°C (50°F)). Cylinders must
be transported according to local rules provided for the transport of dangerous goods.
Cylinder use is subjected to the laws regulating the use of gases and compressed air.
4. The equipment must be overhauled by qualied personnel at the set schedule.
Overhauls must be documented. When making repairs and during maintenance, only
SCUBAPRO replacement parts must be used.
5. Should the equipment be serviced or repaired without complying with procedures
approved by SCUBAPRO or by untrained personnel or not certied by SCUBAPRO, or
should it be used in ways and for purposes other than specically designated, liability for
the correct and safe function of the equipment transfers to the owner/user.
6. If the equipment will be used in cold water (temperature lower than 10°C (50°F)) it will be
necessary to use a regulator suited for such temperatures.