Model
1300NG 1300LPG
Gas Natural Propane
Altitude (Ft.)* 0-4,500 feet*
Input Maximum (Btu/h) 30,000 28,000
Input Minimum (Btu/h) 6,500 14,500
Manifold Pressure (in w.c.) 3.7 10.5
Minimum Supply Pressure
(in w.c.)
5.0 11.0
Maximum Supply Pressure
(in w.c.)
10.0 14.0
Main Burner Injector Marking 850 300
Pilot Injector Marking 51 30
Min. Rate By-Pass Screw 125 125
Burner identi cation
VOGUE
4002604-01
©2012, Miles Industries Ltd.
Gas Conversion Kit
1300NGK/NPK
Installation Instructions
This appliance is certi ed for use from 0–4500 feet. For
altitudes above 4500 feet, see local codes.
Kit Contents
1 Pilot injector
1 Burner
1 Main burner elbow injector
1 Set of conversion labels
1 Set of air shutter
Tools Required
• Wrenches, to disconnect gas line
• Phillips (+) screwdriver, to remove burner module
• Small (jewelers size) at blade screwdriver, to set
pressure
• Small at blade screwdriver, to release pressure tap
on valve
• Nut driver 8 mm or 5/16”, to remove burner nuts
• Needle nose pliers, to remove by-pass screw
• Hex (Allen) wrench, 4 mm or 5/32”, to remove pilot
injector
• Manometer, to set pressure when regulator is integral
with valve
Speci cations
Use with with Valor Models 1300 Heaters ONLY
WARNING
This conversion kit shall be installed by a
quali ed service agency in accordance with
the manufacturer’s instructions and all appli-
cable codes and requirements of the authority
having jurisdiction. If the information in these
instructions is not followed exactly, a re, ex-
plosion or production of carbon monoxide may
result causing property damage, personal in-
jury or loss of life. The quali ed service agency
is responsible for the proper installation of this
kit. The installation is not proper and complete
until the operation of the converted appliance
is checked as speci ed in the manufacturer’s
instructions supplied with the kit.
Use this manual in conjunction with the instal-
lation manual supplied with the appliance.