7
TROUBLESHOOTING:
Problem/Possible Cause/Remedy
Travel Cooler/Warmer is not functioning as cooler or warmer (fan is not turning)
Accessory outlet of DC power supply is not functioning -check by plugging in a
12 volt DC appliance. If not, clean accessory outlet and re-connect the Travel
Cooler/Warmer.
• Fuse or circuit breaker in accessory outlet is open. Reset breaker or check fuse,
and replace fuse if necessary.
• Ignition is switched off - start engine or switch ignition to “accessory” position.
Fuse in unit’s power cord is blown - see Fuse Replacement section for location
of fuse and instructions for checking and replacing fuse.
- Cooler/warmer is not cooling or heating properly (fan is not turning).
Fan is defective. Call Vector
®
Customer Service department for
return/replacement instructions. This unit is not user-serviceable, it must be
returned to Vector Manufacturing for professional service or repair. Any
attempt to service by user will void warranty.
- Cooler/warmer is not cooling or heating, but fan is turning
Cooling unit is defective. Call Vector
®
Customer Service department for
return/replacement instructions. This unit is not user-serviceable, it must be
returned to Vector Manufacturing for professional service or repair. Any
attempt to service by user will void warranty.
- Travel Cooler/Warmer takes longer than 120 minutes to reach desired inside
temperature
• Low battery or supply voltage.
• Unit will attain desired temperature more efficiently if items are pre-heated or
pre-chilled.
• Fan area is blocked - Move unit or object
SPECIFICATIONS:
Capacity . . . . . . . . . . . . . 10.5 Liter / 2.8 Gallons (US)
Power Supply: . . . . . . . . . 12 volt DC
Power Cord: . . . . . . . . . . 7’, with 12 Volt DC accessory plug and 5 Amp fuse
Amperage draw: . . . . . . . 4 Amperes (approx. 48watts)
Cooling Performance: . . . . Cools down to as much as 40ºF below surrounding air
Warming Performance: . . Warms to 60°F above surrounding air.
High Temperature Limit: . . Automatic ON/OFF.
Cold/Heat Transfer: . . . . . Temperature-efficient, aluminum-coated liner
Insulation: . . . . . . . . . . . . CFC-free polyurethane liner
Heat Dissipation: . . . . . . . Built-in fan with long-life, brushless motor
Warm/Cool System: . . . . Non-wearing thermoelectric