P01: Read lamp brightness (1: the darkest; 3: the brightest)
P02: Kilometer unit, 0; Kilometer. 1: Mile
P03: Voltage unit: 24V, 36V, 48V,
P04: Holding Ready Period: 0 never hold, other figures indicate holding
ready period, time interval is 1-60 minutes)
P05: Gear: 0: 3 level mode,
1: 5 level mode,
2: 9 level mode,
P06: Wheel Diameter: Unit, inch; Sensitivity 0.1
P07: Magnetic Steel Number for Speed Test Range: 1-100
P08: Range: 0-100km / s, 100 means there is no speed limit
1. Communication status (Auditor control): Riding speed is fixed as a
limited value. Error Value: ± 1km / s (valid for assistant power / speed)
Above indicated values are measured with metric unit (kilometer). When
measuring unit (mile) is changed, speed value that is seen on panel, is
automatically passed to related imperial unit, however, speed limit value on
unit interface is not changed based on that.
P09: Zero / Zero Out beginning adjustment, 0: Beginning. 1: Zero Out
beginning adjustment P10: Riding Mode Adjustment
0: Power rider- Special gear of assistant rider decides assistant power
value. In that case, start-up support assistant does not work.
1: Electric Rider- The vehicle is ride with start-up support assistant. In
that case, power gear does not work.
2: Power rider + Electric Rider- Electric rider is non-operational
P11: Assistant Power Sensitivity 1-24
P12: Assistant Power Intensity 0-5
P13: Number of Magnet 5/8/12pcs
P14: Assumed current limit value 12A: Ranger 1-20A
Adjustments
Note:
2. FUNCTIONS