Starting the engine
20
Starting method EMS 2
The pre-heating time is adjusted to suit the engine
temperature, and can last for up to 50 seconds both
before and after starting.
The starter motor connection time is maximized to 30
seconds. After that, the starter motor circuit is cut for
80 seconds to protect the starter motor against over-
heating.
NOTE! Preheating must be activated at temperattures
below 0°.
With pre-heating
1. Depress the “ON/OFF” button (6).
2. Press the “SEL” button (7) to come to the main
menu.
3. Scroll down to Preheat with button (9). Press the
“SEL” button (7).
4. In the pre-heat menu, press the “SEL” button (7)
to select pre-heating. The text “Preheat active
please wait” is shown in the display.
5. Wait until the text has gone out and then press
the “START” button (2).
Without pre-heating
1. Depress the “ON/OFF” button (6).
2. Press the “START” button (2).
Leave the engine to idle for the first 10 seconds. Then
warm the engine up at low speed and under low load.
IMPORTANT! Never race the engine when it is
cold.
2
6
7
9

Other manuals for Volvo Penta TAD1242GE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Volvo Penta TAD1242GE and is the answer not in the manual?

Volvo Penta TAD1242GE Specifications

General IconGeneral
BrandVolvo Penta
ModelTAD1242GE
CategoryEngine
LanguageEnglish

Related product manuals