Engine Shutdown
During longer breaks in operation, the engine must be warmed up at least once every two weeks. This prevents
corrosion in the engine. If you expect the engine to remain unused for two months or more, it must be preserved:
Refer to the chapter Storage, page 87.
Before Engine Shutdown
Let the engine run at high idle (1500 or 1800rpm) for a
minimum of 5 minutes before the shutdown after
normal use. Normal use is defined as minimum 50%
load. After use with less than 50% load, high idle for
approximately 3 minutes is sufficient. This allows
engine temperature equalization and prevents boiling
once stopped and also allows the turbochargers to cool
down. This contributes to long, fault-free service life.
NOTICE! Do not turn off the main switch within 30
seconds after turning off the ignition. This is in order to
save engine data to the engine control unit.
Stop the Engine
TAD1640VE-B, TAD1641VE-B, TAD1642VE-B,
TAD1643VE, TAD1650GE, TAD1650VE,
TAD1651GE, TWD1643GE, TWD1652GE,
TWD1653GE
Disengage the clutch (if possible).
Depress the STOP-button (5).
TAD1641GE-B, TAD1642GE-B, TAD1643VE-B,
TAD1650VE-B, TAD1651VE, TWD1644GE,
TWD1645GE
1 Disengage the clutch, if possible.
2 Press the STOP button to turn off the engine.
3
Press the
button to turn off the ignition.
START STOP
OK
P0018811
47711296 01-2019 © AB VOLVO PENTA 43