11 Servicing and maintenance
Do not spray the device and the surrounding area
(panels, base) using a water hose, steam-jet air ejec-
tor or high-pressure cleaner.
Clean the control panel and filter cover with a damp cloth.
Clean the stainless steel coverings with a stainless steel cleaner.
We recommend using Winterhalter C 122 universal grease solvent
and stainless steel cleaner such as Winterhalter C 162 Stainless
Steel Polish in the pressurized spray can.
Do not use corrosive products, acids, steel wool or wire brushes.
Do not use abrasives or abrasive cleaners.
We recommend that you have an authorised service technician
service the device at least once a year.
Cleaning/descaling breather
Check the breather (1) every six months for
dirt and scaling.
Where required, clean, and/or descale with a
standard decalcification agent.
If necessary, commission a service technician
to carry this out.
Consumable parts
The following parts are consumable partss and must be replaced at
regular intervals.
Exchange annually ( 10).
If the following warning appears on the display:
Access the error memory ( 9.3).
If the EVT 24 is listed, the membranes must be
replaced by an authorised service technician.
12 Technical data
Admissible noise level under normal oper-
ating conditions
Filter capacity (1 mg/l Cl
2
)
Operating conditions
Storage temperature in preserved
condition
Maximum height of the installation location
above sea level
Threshold values for the mains water
Maximum inlet water temperature
Maximum total hardness (TH)
Electrical conductivity (at 25 °C)
Power supply
Fuse (electronic operating panel)
Water dispenser
Volume flow of osmosis water at an inlet
water temperature of 15 °C
Yield
The yield depends upon the total hardness (°dH) and the conductivi-
ty (µS/cm) of the mains water. During commissioning, the authorised
service technician will install the correct capillary in the interior of the
device.
13 Installation and connection
13.1 Installation
The device must be installed in an upright position. The maximum
permitted tilted position is 10 mm.
The installation site must be frost-resistant to keep the water
supply systems from freezing.
13.2 Dimensions and position of the connections
Rear view
Water inlet (mains water) G ¾“, external thread
Water drain (waste water), DN 10
Water outlet (osmosis water) G ¾” external thread
Connection for on-site equipotential bonding system