12 MEASURES TO SATISFY THE EMC DIRECTIVES
E-13
12 MEASURES TO SATISFY THE EMC DIRECTIVES
This section describes the measures required for NS115 Module to conform to EMC Directives:
EN50081-2 and EN50082-2.
MECHATROLINK-II Communication Cable
For MECHATROLINK-II communication (CN6A, CN6B) connector, use the connector for
special use.
Max. cable length is 50 m.
Fully Closed Encoder Cable
For fully closed encoder (CN4) connector, use the following connector.
Use the twisted pair shielded cable.
Connector: 54306-2011 (Made by Molex Japan)
Connector case: 54331-0201 (Made by Molex Japan)
The Core on the Cable
Attach the core on the cable as shown below:
Cable line and the line position where the core are attached are shown below.
Core Model ESD-SR-25
Quantity 1
Turn 2
Manufacturer Tokin
Cable Name Mounting Position of Core
MECHATROLINK-II Communication Cable Near the host controller and SERVOPACK side
Fully Closed Encoder Cable Near the SERVOPACK side
Cable
Core

Other manuals for YASKAWA E-II Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA E-II Series and is the answer not in the manual?

YASKAWA E-II Series Specifications

General IconGeneral
BrandYASKAWA
ModelE-II Series
CategoryServo Drives
LanguageEnglish

Related product manuals