036-21671-001 Rev. A (0106)
Unitary Products Group 3
NOTES:
1. Airflow expressed in standard cubic feet per minute (CFM) and in cubic meters per minute (m
3
/min).
AIR FLOW DATA
HIGH / LOW SPEED COOLING AND HEAT PUMP CFM
PC9B12N060DH11 PC9B12N080DH11
JUMPER SETTINGS
CFM CFM
High Low High Low COOL Tap ADJ Tap
1330 900 1310 890 A B
1130 800 1100 740 B B
1220 850 1220 830 A A
1040 730 1000 670 B A
1120 770 1090 720 A C
920 650 900 610 C B
950 660 880 610 B C
740 540 680 510 D B
860 610 810 580 C A
690 540 630 500 D A
790 570 730 530 C C
630 530 590 500 D C
PC9C16N080DH11
PC9C16N100DH11
PC9C20N100DH11
JUMPER SETTINGS
CFM CFM
High Low High Low COOL Tap ADJ Tap
1660 1110 2210 1480 A B
1550 1050 1780 1180 B B
1610 1070 2040 1350 A A
1440 960 1620 1050 B A
1470 990 1840 1250 A C
1370 920 1560 1010 C B
1290 850 1470 940 B C
1130 790 1370 890 D B
1230 850 1460 930 C A
1050 720 1250 790 D A
1110 760 1310 810 C C
950 660 1090 690 D C
PC9D20N120DH11
JUMPER SETTINGS
CFM
High Low COOL Tap ADJ Tap
2280 1510 A B
1860 1190 B B
2090 1370 A A
1630 1060 B A
1880 1250 A C
1620 1030 C B
1500 960 B C
1410 880 D B
1490 920 C A
1290 790 D A
1360 840 C C
1140 690 D C
All CFM’s are shown at 0.5” w.c. external static pressure.These units have variable speed motors that automatically adjust to provide constant CFM from 0.0” to 0.6” w.c.
static pressure. From 0.6” to 1.0” static pressure, CFM is reduced by 2% per 0.1” increase in static. Operation on duct systems with greater than 1.0” w.c. external static
pressure is not recommended.
NOTE: At some settings, LOW COOL airflow may be lower that what is required to operate an airflow switch on certain models of electronic air cleaners. Consult the
instructions for the electronic air cleaner for further details.