567175-YTG-E-0512
2 Johnson Controls Unitary Products
All dimensions are in inches. They are subject to change with-
out notice. Certified dimensions will be provided upon request.
* Expander fitting required for 1-1/8” line set.
PHYSICAL AND ELECTRICAL DATA
MODEL CZF02413(C) CZF03013(C) CZF03613(C) CZF04213(C) CZF04813(C) CZF06013(C)
Unit Supply Voltage 208-230V, 1 60Hz
Normal Voltage Range
1
187 to 252
Minimum Circuit Ampacity 17.3 18.1 22.9 23.7 27.7 29.5
Max. Overcurrent Device Amps
2
30 30 40 40 45 50
Min. Overcurrent Device Amps
3
20 20 25 25 30 35
Multi-Stage Compressor No No No No No No
Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll
Compressor Amps
Rated Load 13.4 14.1 17.3 17.9 21.1 21.4
Locked Rotor 58.3 73.0 96.7 112 106 135
Crankcase Heater No No No No No No
Factory External Discharge Muffler No No No No No No
Factory External Check Valve No No No No No No
HS Kit Required with TXV
4
No No No No No No
Fan Motor Amps Rated Load 0.5 0.5 1.3 1.3 1.3 2.8
Fan Diameter Inches 22 22 22 22 24 24
Fan Motor
Rated HP 1/15 1/15 1/4 1/4 1/4 1/3
Nominal RPM 850 850 850 850 850 917
Nominal CFM 2020 2045 3240 3300 3800 3900
Coil
Face Area Sq. Ft. 14.10 13.97 16.12 19.34 22.82 22.82
Rows Deep 1 1 1 1 1 1
Fins / Inch 23 23 23 23 23 23
Liquid Line Set OD (Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8
Vapor Line Set OD (Field Installed) 3/4 3/4 3/4 7/8 7/8 1-1/8
Unit Charge (Lbs. - Oz.)
5
3 - 12 4 - 6 5 - 0 6 - 4 6 - 5 6 -14
Charge Per Foot, Oz. 0.62 0.62 0.62 0.67 0.67 0.75
Operating Weight Lbs. 159 166 192 209 225 235
1. Rated in accordance with ANSI/AHRI Standard 110-2002, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model.
5. The Unit Charge is correct for the outdoor unit, matched indoor coil, and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet,
add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
VAPOR
LIQUID
2-3/8
3-1/8
6-1/2
C
A
B
Unit
Model
Dimensions
(Inches)
Refrigerant Connection
Service Valve Size
A B C Liquid Vapor
024 29-1/2 37 31
3/8”
3/4”030 29-1/2 37 31
036 33-1/2 37 31
042 39-1/2 37 31
7/8”
048 39-1/2 42 34
060 39-1/2 42 34 7/8” *