EasyManuals Logo
Home>York>Air Conditioner>CZH

York CZH User Manual

York CZH
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
835965-UIM-C-0814
10 Johnson Controls Unitary Products
FIGURE 11: Thermostat Wiring – Single Stage Air Conditioner (with AC control) – Modulating Furnace
– Modulating Furnace
Single Stage Air Conditioner (with AC control)
(Y,L,C)*(8,L)C
T*(8,L)C
T*9C
(Y,L,C)*9C
ID MODELS
Jumper 1 must be set
to “GAS/ELEC”
Y1
First Stage
Compressor
W2
Second Stage Heat
G
Fan
S1-THSU21P1b
THERMOSTAT
R
24 – Volt Hot
W1/O/B
First Stage Heat
C
24 – Volt Common
Jumper 3 must be set
to “GAS”
SINGLE STAGE
AIR
CONDITIONER
C
24 – Volt Common
R
24 – Volt Hot
Y1
First Stage Compressor
Y2
Second Stage
Compressor
SINGLE STAGE
AIR CONDITIONER
External Humidistat
(Optional)
Open on Humidity Rise
C
24 – Volt Common
R
24 – Volt Hot
Y1
First Stage Compressor
MODULATING
FURNACE CONTROL
G
Fan
MODULATING
FURNACE
Y/Y2
Second or Full
Stage Compressor
DHUM
Dehumidification-
Open on Humidity Rise
W
Modulating Heat
Move HUMIDISTAT
jumper to “YES”
if humidistat is to be used.
LO COMP
Single Stage
Compressor (OUT)
O
Reversing Valve
Energized in Cool
HI COMP
Second Stage
Compressor (OUT)
HEATPUMP jumper must
be set to “NO”
A0209-002

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the York CZH and is the answer not in the manual?

York CZH Specifications

General IconGeneral
BrandYork
ModelCZH
CategoryAir Conditioner
LanguageEnglish