EasyManuals Logo
Home>York>Air Conditioner>DNZ 024

York DNZ 024 User Manual

York DNZ 024
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
66433-YIM-B-1004
Unitary Products Group 13
FIGURE 6 - UNIT DIMENSIONS - FRONT
3-3/4
2-1/2
47-1/4
1-1/2
2-5/8
3-1/3
5-3/8
11
12-3/4
49-1/8
A
2-3/8
VENTAIROUTLETHOOD
BLOWERSERVICE
ACCESSCOMPARTMENT
PANEL
GASSUPPLY1-1/4"DIA.
HOLE(1/2"NPTI
CONN
ECTION)
UNITCONDENSATE
CONNECTION3/4"NPTI
(TRAPRECOMMENDED)
B
HIGHVOLTAGE
CONN.1-3/8"DIA.
KNOCKOUT
HIGHVOLTAGE
CONN.7/8"DIA.
KNOCKOUT
GASSUPPLY1-1/4"DIA.
KNOCKOU
T(1/2"NPTI
CONNECTION)
LOWVOLTAGECONN.
1-3/8"DIA.KNOCKOUT
X7/8"HOLE
CONDENSERCOIL
REFRIGERANT
CONNECTIONS
COMBUSTIONAIR
INLETLOUVERS
FRONT
GAS/ELECTRICCONTRO
L
SERVICEACCESS
COMPARTMENTPANEL
(OVERALL)
(OVERALL)
All dimensions are in inches.
They are subject to change with-
out notice. Certified dimensions
will be provided upon request.
TABLE 9: UNIT DIMENSIONS FRONT
UNIT SIZE
DIMENSION
“A” “B”
024, 030, 036 33-1/2 18-1/4
042, 048, 060 41-1/2 23-1/8
TABLE 10: UNIT MINIMUM CLEARANCES
1
2
1.
A 1” clearance must be provided between any combus-
tible material and the supply air ductwork.
2.
The products of combustion must not be allowed to
accumulate within a confined space and recirculate.
CLEARANCES
FRONT 36”
BACK 0”
LEFT SIDE (Filter-Access) 24”
RIGHT SIDE 12”
BELOW UNIT
3
3.
Units may be installed on combustible floors made from
wood or class A, B, or C roof covering material.
0”
ABOVE UNIT
4
4.
Units must be installed outdoors. Overhanging struc-
tures or shrubs should not obstruct condenser air dis-
charge outlet.
36” (For Condenser Air Discharge

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the York DNZ 024 and is the answer not in the manual?

York DNZ 024 Specifications

General IconGeneral
BrandYork
ModelDNZ 024
CategoryAir Conditioner
LanguageEnglish

Related product manuals