EasyManuals Logo
Home>York>Air Conditioner>FC9C UP Series

York FC9C UP Series User Manual

York FC9C UP Series
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
292278-UIM-A-0108
Unitary Products Group 11
FIGURE 7: Thermostat Chart – Two Stage AC - Variable Speed Modulating Furnace
Optional Harness
AC 26C Two Stage Air Conditioner – Variable Speed Modulating Furnace
TWO STAGE
AIR
CONDITIONER
C
24 – Volt Common
R
24 – Volt Hot
Y1
First Stage Compressor
Y2
Second Stage
Compressor
C
24 – Volt Common
Y1
First Stage Compressor
L
Malfunction Light
Y2
Second Stage
Compressor
G
Fan
*PP32U71124
*PP32U72124
THERMOSTAT
R
24 – Volt Hot
W2
Second Stage Heat
DHM
Dehumidification
HM
Humidistat
Step 1 of Thermostat User
Configuration Menu must
be set to MLTISTG
E/W1
First Stage Heat
24VAC Humidifer
(Optional)
C
24 – Volt Common
R
24 – Volt Hot
Y1
Single Stage Compressor
VARIABLE SPEED
MODULATING
FURNACE CONTROL
G
Fan
VARIABLE SPEED
MODULATING
FURNACE
Y/Y2
Second or Full
Stage Compressor
HUM
Dehumidification-
Open on Humidity Rise
W
Modulating Heat
Part Numbers:
SAP = Legacy
171334 = 031-09153
1
1
Move HUMIDISTAT
jumper to “YES
if humidistat is to be used.
FL9C
FC9C
PC9
ID MODELS
Comfort Alert Interface
(two pin connector)
E2/P Switch must be in the
E2 position
Step 16 of Thermostat
Installer Table Menu
must be set to ON to use
Comfort Alert Features
Only applies to
*PP32U72124

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the York FC9C UP Series and is the answer not in the manual?

York FC9C UP Series Specifications

General IconGeneral
BrandYork
ModelFC9C UP Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals