036-21215-003 Rev. B (1202)
4 Unitary Products Group
- = Not applicable
COOLING CAPACITY - With Air Handler Coils
UNIT MODEL
AIR HANDLER
COIL
1
MODEL
COOLING
MODEL
ELECTRIC
2
HEAT KW
W
RATED
CFM
NET MBH
SEER
W/O TXV
SEER
+ TXV
3
EER
TOTAL SENS.
1 PH 12 SEER AC WITH N1AH / G2FD
H4AH024S06 N1AHB0806 2,5,8,10 17 G2FD024(S,H)17 850 24.0 18.0 12.00 - 10.80
H4AH024S06 N1AHB0806 2,5,8,10 17 G2FD030(S,H)17 850 24.2 18.3 12.00 - 10.70
H4AH030S06 N1AHB1206 5,8,10,15,19 17 G2FD030(S,H)17 1060 28.8 21.5 11.50 - 10.25
H4AH030S06 N1AHB1206 5,8,10,15,19 17 G2FD036(S,H)17 1060 30.2 22.6 12.00 - 10.50
H4AH036S06 N1AHB1206 5,8,10,15,19 17 G2FD036(S,H)17 1250 36.0 27.0 12.00 - 10.85
H4AH036S06 N1AHB1206 5,8,10,15,19 17 G2FD046(S,H)17 1250 35.6 26.8 12.00 - 10.90
H4AH036S06 N1AHD1406 5,8,10,15 24 G2FD048(S,H)24 1250 36.8 27.7 12.20 - 11.20
H4AH042S06 N1AHC1606 5,8,10,15,20 21 G2FD042(S,H)21 1350 40.5 30.0 12.00 - 11.00
H4AH042S06 N1AHC1606 5,8,10,15,20 21 G2FD048(S,H)21 1350 41.5 31.0 12.30 - 11.40
H4AH048S06 N1AHC1606 5,8,10,15,20 21 G2FD048(S,H)21 1620 48.0 35.3 12.20 - 11.30
H4AH048S06 N1AHD2006 8,10,15,20,25,30 24 G2FD060(S,H)24 1620 48.0 35.3 12.30 - 11.30
H4AH060S06 N1AHD2006 8,10,15,20,25,30 24 G2FD060(S,H)24 1850 59.0 43.4 12.00 - 10.50
H4AH060S06 N1AHD2006 8,10,15,20,25,30 24 G2FD061H24 1850 59.5 45.0 12.10 - 10.65
1 PH 12 SEER AC / N1VS - VARIABLE SPEED
H4AH024S06 N1VSB12 10,15,18 17 G2FD024(S,H)17 820 24.6 18.4 13.00 - 12.00
H4AH024S06 N1VSB12 10,15,18 17 G2FD036(S,H)17 820 24.6 18.7 13.00 - 12.20
H4AH030S06 N1VSB12 10,15,18 17 G2FD030(S,H)17 1035 29.2 22.0 12.30 - 11.30
H4AH030S06 N1VSB12 10,15,18 17 G2FD036(S,H)17 1070 30.8 23.3 13.00 - 11.40
H4AH036S06 N1VSB12 10,15,18 17 G2FD036(S,H)17 1250 36.4 27.1 12.60 - 11.40
H4AH036S06 N1VSB12 10,15,18 17 G2FD046(S,H)17 1230 36.0 27.3 12.50 - 11.50
H4AH036S06 N1VSC16 10,15,18 21 G2FD048(S,H)21 1220 37.4 28.3 13.50 - 12.10
H4AH042S06 N1VSC16 10,15,18 21 G2FD042(S,H)21 1350 41.0 30.6 13.00 - 11.80
H4AH042S06 N1VSC16 10,15,18 21 G2FD048(S,H)21 1350 42.0 31.3 13.30 - 12.20
H4AH048S06 N1VSC16 10,15,18 21 G2FD048(S,H)21 1590 48.5 36.1 12.90 - 11.90
H4AH048S06 N1VSD20 10,15,18,30 24 G2FD060(S,H)24 1600 48.0 36.1 13.00 - 11.85
H4AH060S06 N1VSD20 10,15,18,30 24 G2FD060(S,H)24 1600 58.5 44.5 12.55 - 10.90
H4AH060S06 N1VSD20 10,15,18,30 24 G2FD061H24 1600 59.0 45.7 12.65 - 11.10
1 PH 12 SEER AC / F2RP / RC / FP / FC / FV
4,5
H4AH024S06 F2RC/FC030 5,8,10,15 18 - 850 23.2 16.7 11.70 - 10.60
H4AH024S06 F2RP/FP024 5,8,10 18 - 850 24.0 18.0 12.00 - 10.80
H4AH024S06 F2RP/FP030 5,8,10,15 18 - 850 24.6 18.6 12.00 - 10.75
H4AH030S06 F2RC/FC036 5,8,10,15 21 - 1060 28.8 21.5 11.50 - 10.25
H4AH030S06 F2RP/FP030 5,8,10,15 18 - 1060 28.8 21.5 11.50 - 10.30
H4AH030S06 F2RP/FP036 5,8,10,15,19 18 - 1060 29.6 22.1 11.50 - 10.40
H4AH036S06 F2RP/FP036 5,8,10,15,19 21 - 1250 35.4 26.6 11.90 - 10.80
H4AH036S06 F2RP/FP042 5,8,10,15 21 - 1250 35.4 26.6 11.80 - 10.70
H4AH036S06 F2FP048 5,8,10,15,20,25 24 - 1250 36.6 27.5 12.00 - 10.90
H4AH042S06 F2RP/FP042 5,8,10,15 21 - 1350 40.5 30.0 12.00 - 10.90
H4AH042S06 F2FP045 5,8,10,15 24 - 1350 41.5 31.0 12.30 - 11.40
H4AH042S06 F2FP048 5,8,10,15,20,25 24 - 1350 41.0 30.6 12.00 - 11.20
H4AH042S06 F2FV060 8,10,15,20,25 24 - 1350 42.0 31.7 14.00 - 12.25
H4AH048S06 F2FP048 5,8,10,15,20,25 24 - 1620 47.5 34.9 12.00 - 11.00
H4AH048S06 F2FP060 5,8,10,15,20,25 24 - 1620 47.5 34.9 12.00 - 10.80
H4AH048S06 F2FV060 8,10,15,20,25 24 - 1605 48.5 36.1 13.50 - 12.50
H4AH060S06 F2FP060 5,8,10,15,20,25 24 - 1850 59.0 43.4 11.50 - 10.10
H4AH060S06 F2FV060 8,10,15,20,25 24 - 1860 60.5 44.5 13.00 - 11.50
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input
in watt-hours during the same period.
1 G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2 Single phase units require single phase 2HK heaters.
3 TXV = Use 1TV700 Series Kit.
4 To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC
.
models. All ratings remain the same.
5 FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard.