12 Johnson Controls Unitary Products
5151065-YTG-H-0118
LIMITATIONS
These units must be wired and installed in accordance with all
national and local safety codes.
Voltage limits are as follows:
Airflow must be within the minimum and maximum limits
approved for electric heat, indoor coils and outdoor units.
Air Handler Voltage
1
Normal Operating Voltage
Range
1. Rated in accordance with ARI Standard 110, utilization range “A”.
208/230-1-60 187-253
TYPICAL APPLICATIONS
A0346-001
UPFLOW
DOWNFLOW
HORIZONTAL RIGHT
HEAT
HORIZONTAL LEFT
HEAT
HEAT
HEAT
HEAT
COMBUSTIBLE FLOOR BASE ACCESSORY
Floor Base
Models
Used with
Dimensions
ABC
1FB1917 MVC08B, MVC12B 19.9 14.0 14.9
1FB1921 MVC12C, MVC16C 23.4 17.5 18.4
1FB1924 MVC14D, MVC20D 26.9 21.0 21.9
'2:1)/2: