Maintenance
Clean the air filter
Pull the filters upward to remove them from the Intake Grill.
Clean the air filter: Remove the dust from the filters by vacuum cleaner or washing
them. After washing, allow the air filters to dry thoroughly in an area protected from
sunlight.
Re-attach the air filters to the Intake Grill. Press the two buttons on the filters until
you hear a sound of click.
When used for extended periods, the unit may accumulate dirt inside, which reduces its performance. We recommend
that the unit is inspected regularly, in addition to your own cleaning and care. For more information, consult authorized
service personnel.
When cleaning the unit's body, do not use water hotter than 40 C, harsh abrasive cleansers, or volatile agents like
benzene or thinner.
Do not expose the unit body to liquid insecticides or hairsprays.
When shutting down the unit for one month or more, first allow the Fan mode to operate continuously for about half a
day to allow internal parts to dry thoroughly.
Maintenance of indoor units
1.
2.
3.
Followings are not problems
Sound of water flowing is not a problem.
Sound of cracking is heard.
Smell are generated.
During operation, white fog or steam
comes out from the indoor unit.
No outlet air or fan speed can't be changed
in dry mode.
In cooling operation, unit switches to
blowing operation.
Won't start?
In heating operation, water or steam
are blown out of outdoor unit.
In heating operation, indoor fan won't stop
even if unit is stopped.
During unit operation or at stop, a swishing or gurgling noise may be heard.
This noise is generated by refrigerant flowing in the system.
Unit will not restart after stop.
During unit operation, a cracking noise may be heard.
This noise is generated by the casing expanding or shrinking because of
temperature changes.
This is because the system circulates smells from the interior air such as
the smell of cigarettes or the painting on the furniture.
When unit is running at places like restaurant, etc. where dense edible oil
fumes always exist, this will happen.
To prevent frost from accumulating on indoor heat exchanger, unit will switch
to blowing operation for a while then resume cooling operation.
Though ON/OFF button is set to ON, the unit won't
resume cooling, dry or heating operation in 3 min
after it is stopped, this is because of
3-min-delay protection circuit.
Please wait 3 minutes
Unit will reduce fan speed repeatedly and automatically if room temp. is
too low in dry operation.
This occurs when frost accumulated on the outdoor unit is removed.
(during defrosting operation)
After unit stop, indoor fan will go on running until indoor unit cools down.
Troubleshooting

Questions and Answers: