Page 27
This feature allows the thermostat to display temperature in Fahrenheit or Celsius.
Fahrenheit or Celsius (setup step 56)
Control To Temp Source (Setup Step 39)
This feature allows the user to specify which sensor source the thermostat
will use to measure room temperature. Thermostat: Uses the internal thermostat
sensor only. Remote Sensor: Uses wireless or wired sensors only. Average Of
Remote Sensor And Thermostat: Averages the temperatures of the remote sensor(s)
and the thermostat. NOTE: If a remote sensor is being used, the degree icon on the
large room temperature display will blink.
temperature
Fault Type (setup step 72)
This step allows the FAULT terminal on the thermostat to be configured for three
different settings:
(This feature not available on all models)
YORK - Fault alerts 2 or 3 are interpreted from a Yorkguard Heat Pump Control.
COMFORT ALERT - Fault alerts are controlled by the Comfort Alert accessory.
Installer Setup
Dual Fuel Changeover Delay (Setup Step 54) - (0 - 90) Specifies the number of
seconds the heat pump is allowed to continue running after a fossil fuel heat source
has been engaged.
Dual Fuel Changeover on Outdoor Temp (Setup Step 52) - ON, the change from Heat
Pump to a fossil fuel source of heat will be based on outdoor temperature. OFF, Heat
Pump heating will be terminated when there is a demand for third stage heat.
Dual Fuel Balance Point (Setup Step 53) - (5 - 60 ) Specifies the outdoor temperature
at which the heat pump will cease operating and a fossil fuel source of heat is used.
Dual Fuel (Cont.)
NONE - Scrolling display shows ‘FAULT’ when a fault signal is active.
Dual Fuel Safety Timer (Setup Step 51) - On/Off When this feature is set to ON, the
room temperature must rise 1 degree within 60 minutes after a switch to fossil fuel has
been made. If the room temperature does not rise, the fossil fuel system will cease
operating and the heat pump will be restarted.
Setup steps 51-54 will only appear if step 50 is set to ON.