5.3 DESCRIPTION OF PROGRAMMABLE FUNCTIONS (OPTIONS).
Using the CONFIG MENU of the console, it is possible to select from the following
options:
SUBMENU “SET OPTIONS”:
1 HOUR COUNTER:
- RUNNING: The counter registers travel time only.
- KEY ON: The counter registers when the key switch is Closed.
The A1 output for external hourmeter operates according to internal hourmeter. If the
pump contactor is connected (D4), hourmeter output (A1) is activated during lifting as
well.
2 QUICK INVERSION
- BELLY: Quick inversion is activated while the Belly Button is
pressed.
- TIMED: Quick inversion is activated, while the Belly Button is
pressed, maximum for 2 second.
3 AUX OUTPUT #1:
-FREE: A4 output is not used: the controller carry out monitor
function as described at the paragraph 2.5.
-BRAKE: A4 output drives an electromechanical brake. The con-
troller does not carry out monitor function, but locks the
brake while in rest or alarm status.
MENU