Technical data temperature sensors
Platinum resistance Pt 1000
Sensor diameter/type mm Standard: 5,0 (DS according to EN 1434); other sizes on demand
Temperature range °C 0 - 105
Cable length m 1,5 (opt. 5)
Installation
forward
temp.-sensor
by direct immersion or by immersion sleeves (in case of existing measuring points )
return
temp.-sensor
by direct immersion or by immersion sleeves (in case of existing measuring points);
optionally integrated in flow sensor
ZENNER International GmbH & Co. KG declares
that this product with the number of the EC type-
examination certicate DE-12-MI004-PTB010
complies with the requirements of the EC direc-
tives 2004/22/EC (Measuring instruments direc-
tive) and 89/336/ EEC (electro-magnetic
compa-
tibility).
Electro-magnetic interference
zelsius
®
C5-ISF fulls the national and interna-
tional requirements for interference resistance.
To avoid malfunctions due to other interfer-
ences, do not install uorescent lamps, switch
cabinets or electric devices such as motors or
pumps in the immediate vicinity of the meter
(minimum distance 1 m). Cables leaving the
meter should not be laid parallel to live cables
(230V) (minimum distance 0.2 m).
Care instructions
Clean plastic surfaces with a damp cloth only.
Do not use any scouring or aggressive cleaning
agents! The device is maintenance-free during
the service life. Repairs can only be made by the
manufacturer.
The most up-to-date information about this pro-
duct and of our installation notice can be found at
www.zenner.com.
Pulse inputs and outputs
(optional)
By meters with pulse outputs, the pulse value
can be called up in the display (see the display
overview, Level 4).
The pulse value of the outputs is permanently set
and corresponds with the last position of the as-
sociated display value.
Example:
Output 1 = energy output
Energy display = XXXXX.XXX
Last position = 0.001 MWh = 1 kWh
Output pulse = 1 kWh
In 1…3 Out 1…3
Eingang
GNDGND
Ausgang
In 1…3 Out 1…3
Eingang
GN
DG
ND
Ausgang

Other manuals for Zenner zelsius C5-ISF

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zenner zelsius C5-ISF and is the answer not in the manual?

Zenner zelsius C5-ISF Specifications

General IconGeneral
BrandZenner
Modelzelsius C5-ISF
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals