Airow Control Technology (ACT)
Some local codes limit the maximum amount of CFM a range hood can move. ACT allows you to control the
maximum blower CFM of select Zephyr Ventilation range hoods without the need for expensive make up air kits.
ACT enables the installer to easily set the maximum blower speed to one of two most commonly specied CFM
levels; 390 or 290 CFM. The usage of ACT may not be necessary for your installation. Please check your local codes
for CFM restrictions.
By default the maximum blower CFM is set to 600 for ZAN, ZRV and ZRO.
By default the maximum blower CFM is set to 685 for ZSA.
To enable ACT
1. Before hood installation, gain access to PC board by following the steps shown in FIG. C.
2. Change plastic jumper positioning as shown in FIG. D to set the desired maximum blower CFM.
3. Re-install PC board & continue with hood installation.
4. Remove the appropriate foil CFM sticker included with the hood literature and place inside the hood body below
the wiring diagram or in another clearly visible location.
NOTE: After re-positioning the jumper and powering on the hood, the CFM cannot be changed again.
To verify if your installer enabled ACT
With hood off, press and hold the power button for three seconds. If 5 LEDs illuminate = defualt max. CFM, if 4 LEDs
illuminate = max. 390 CFM, and if 3 LEDs illuminate = max. 290 CFM.
When ACT is enabled, the number of blower speeds will be reduced. 390 CFM = max. 4 speeds and 290 CFM =
max. 3 speeds.
There should also be a foil label located inside the hood body near the wiring diagram that indicates the blower CFM.
ACT Conversion
CAUTION:
Hood must be disconnected from main power prior to performing the
conversion instructions listed below. Failure to do so could result in
personal injury or damage to the product.
!
PC Board
1
3
5
7
2
4
6
8
Jumper 5-6 or 7-8
DEFAULT POSITION
Default Max. Blower CFM
Jumper 3-4
Max. Blower CFM
390
Jum per 1-2
Jumper Pins
Plastic
Jumper
1
3
5
7
2
4
6
8
1
3
5
7
2
4
6
8
1
3
5
7
2
4
6
8
Max. Blower CFM
290
FIG. C
FIG. D
Models: ZAN, ZRO, ZRV
- Locate PC board box on top of blower housing.
- Remove 2 to 4 screws attaching PC board cover.
Models: ZSA
- Remove aluminum mesh filters.
- Remove 2 to 4 screws attaching PC board cover.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zephyr Essentials ZAN-E30CS and is the answer not in the manual?

Zephyr Essentials ZAN-E30CS Specifications

General IconGeneral
Colorstainless steel
Hood Typewall
Venting Typeconvertible
Temperature Sensorno
Number of Fan Speeds5
Control Typebutton
Delay Startyes
Interior Lightyes
Remote Controlno
Voltage120 volts
Current4 amperes
Weight and Dimensions IconWeight and Dimensions
Depth22 1/16 inches
Height27 inches
Width29 15/16 inches
Net Weight36.2 pounds