Introduction
The Baseline 10/100 Switch is supplied with two mounting
brackets and four screws. These are used for rack mounting the
unit. When mounting the unit, you should take note of the
guidelines given in
Positioning the Baseline 10/100 Switch on
page 3
.
Rack Mounting the Units
The Baseline 10/100 Switch is 1U high and will fit a standard
19-inch rack.
CAUTION: Disconnect all cables from the unit before
continuing. Remove the self-adhesive pads from the
underside of unit, if already fitted.
1 Place the unit the right way up on a hard, flat surface with
the front facing towards you.
2 Locate a mounting bracket over the mounting holes on one
side of the unit (refer to the figure following step 6).
3 Insert the two screws supplied in the mounting kit and fully
tighten with a suitable screwdriver.
4 Repeat the two previous steps for the other side of the unit.
5 Insert the unit into the 19-inch rack and secure with suit-
able screws (not provided).
6 Reconnect all cables.
Refer to the information about LEDs given earlier in this guide to
see if the problem can be identified and rectified. Here are some
common problems that can occur:
Link Status LED not lit for a port that has a connection.
There is a problem with this connection. Check that:
!
The device being connected to is powered on and operating
correctly.
!
The cable is connected at both ends.
!
The cable is not damaged.
!
If the connection is to a workstation, that the workstations
network interface is installed and configured correctly.
All Activity LEDs appear to be lit continually. There may be
broadcast storms on the network.
Remove port connections one at a time, waiting a few seconds
between each port. If the LEDs go off after removing a port
connection, the device that was connected to that port is
introducing an excessive amount of broadcast frames to the
network (some pieces of network equipment operate by sending
out broadcast frames regularly). Refer to the documentation that
accompanies the device for information on disabling the
broadcast operation.
If the problem persists and the unit still does not operate
successfully, contact your supplier with the following information
before returning the unit:
!
Product number and serial number (printed on a label
supplied with the unit)
!
A brief description of the fault
Related Standards
The SuperStack 3 Baseline 10/100 Switch has been designed to
the following standards:
Environmental
Physical
Electrical
MOUNTING KIT INSTRUCTIONS
PROBLEM SOLVING
TECHNICAL INFORMATION
Functional
ISO 8802-3, IEEE 802.3 (Ethernet), IEEE 802.3u (Fast
Ethernet), IEEE 802.3x (Flow Control)
Safety
UL 1950, EN 60950, CSA 22.2 #950, IEC 60950
EMC Emissions
EN 55022 Class A, FCC Part 15 Subpart B Class A,
ICES-003 Class A, VCCI Class A, AS/NZS 3548 Class A,
CNS 13438 Class A
Immunity
EN 55024
Operating Temperature
0–50°C (32–122°F)
Humidity
10–95% (non-condensing)
Width
440 mm (17.3 in.)
Depth
173 mm (6.8 in.)
Height
44 mm (1.7 in.) or 1U
Weight
2.6 kg (5.8 lb)
Mounting
Free standing, or 19in. rack mounted using the mount-
ing kit supplied
Power Inlet
IEC 320
AC Line Frequency
50/60 Hz
Input Voltage
100–240 VAC
Current Rating
1 Amps (maximum)
Maximum Power
Consumption
3C16464C: 49 VA
3C16465C: 88 VA
Maximum Power
Dissipation
3C16464C: 165 BTU/hr
3C16465C: 300 BTU/hr
5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 3Com SuperStack 3 3C16464C and is the answer not in the manual?

3Com SuperStack 3 3C16464C Specifications

General IconGeneral
Brand3Com
ModelSuperStack 3 3C16464C
CategorySwitch
LanguageEnglish

Related product manuals